Service manual


GB
Model AOS241HX
Po�er Supply 1 PH, 230 VAC,60Hz
Connected to Outdoor
Maximum Current 12.2A
Inrush Current 35A
Starting Current 1A
Circuit breaker 30A30AA
Po�er supply �iring - No. x cross section 1 X 3 X 2.5 mm
2
Interconnecting cable - No. x cross section 2 X 4 X 1 mm
2
Model AOM183HX
Po�er Supply 1 PH, 230 VAC,60Hz
Connected to Outdoor
Maximum Current 10.5A
Inrush Current 40A
Starting Current 1A
Circuit breaker 20A
Po�er supply �iring - No. x cross section 1 X 3 X 2.5 mm
2
Interconnecting cable - No. x cross section 2 X 4 X 1 mm
2
Model AOM243HX
Po�er Supply 1 PH, 230 VAC,60Hz
Connected to Outdoor
Maximum Current 13A
Inrush Current 35A
Starting Current 1A
Circuit breaker 30A30AA
Po�er supply �iring - No. x cross section 1 X 3 X 2.5 mm
2
Interconnecting cable - No. x cross section 2 X 4 X 1 mm
2
Note: Inrush current is the current �hen po�er is up. (charging the DC capacitors at outdoor
unit controller).Starting current is the current �hen starting the compressor
NOTE
Power wiring cord should comply with local lows and electrical regulations requirements.
eLeCtRICALDAtA