Service manual
0
GB
Indoor Units Capacity For 24000BTU
Capacity Model
24000BTU AWS241HX
ID COIL ENTERING AIR DB TEMPERATURE [0F]
OD COILENTERING
AIR DB/WB TEM
PERATU RE[
0
F]
DATA 59 68 77
5/3
TC 15680 14455 13475
PI 1.35 1.49 1.63
14/10
TC 17395 16170 15190
PI 1.63 1.76 1.93
20/18
TC 18620 17640 16415
PI 1.85 1.98 2.12
30/28
TC 19355 18375 17150
PI 1.96 2.07 2.20
36/34
TC 19845 18620 17640
PI 2.01 2.15 2.29
45/43
TC 25480 24500 23520
PI 2.12 2.26 2.40
50/48
TC 26950 25970 24745
PI 2.26 2.40 2.54
59/54
TC 28420 27440 26215
PI 2.37 2.48 2.65
59~75
(Protection Range)
TC 85 - 105 % of nominal
PI 80 - 120 % of nominal
Heating Capacity (BTU)---Run Model,230V,Indoor fan at high speed
INDOOR ENTERING AIR DB/WB TEMPERATURE [
0
F]
OUTDOOR
ENTERING AIR DB
TEMPERATURE[0F]
DATA 72/59 75/63 81/66 84/70 90/73
14~68 (protection
range)
TC 80 - 110 % of nominal
SC 80 - 105 % of nominal
PI 25 - 50 % of nominal
77
TC 23232 24672 26208 27744 29280
SC 20640 21000 21480 21840 22320
PI 1.72 1.75 1.78 1.81 1.84
86
TC 22080 23616 25152 26592 28128
SC 20040 20520 20880 21360 21720
PI 1.93 1.96 1.99 2.02 2.05
95
TC 20928 22464 24000 25536 27072
SC 19560 19920 20400 20880 21240
PI 2.11 2.14 2.20 2.23 2.26
104
TC 19872 21408 22848 24384 25920
SC 19080 19440 19920 20280 20760
PI 2.32 2.35 2.38 2.41 2.44
115
TC 18528 20064 21504 23040 24576
SC 18360 18840 19200 19680 20040
PI 2.56 2.59 2.62 2.65 2.71
Cooling Capacity (BTU)---Run Model,230V,Indoor fan at high speed