Service manual

1
GB
Heating Capacity (KW)---Run Model (Unit A,B,C or D),230V,Indoor fan at high speed
ID COIL ENTERING AIR DB TEMPERATURE [
0
F]
OD COILENTERING
AIR DB/WB TEM
PERATU RE[
0
F]
DATA 59 68 77
5/3
TC 8960 8260 7700
PI 0.66 0.73 0.80
14/10
TC 9940 9240 8680
PI 0.80 0.87 0.95
20/18
TC 10640 10080 9380
PI 0.91 0.97 1.04
30/28
TC 11060 10500 9800
PI 0.96 1.02 1.08
36/34
TC 11340 10640 10080
PI 0.99 1.06 1.12
45/43
TC 14560 14000 13440
PI 1.04 1.11 1.18
50/48
TC 15400 14840 14140
PI 1.11 1.18 1.25
59/54
TC 16240 15680 14980
PI 1.16 1.22 1.30
59~75
(Protection Range)
TC 85 - 105 % of nominal
PI 80 - 120 % of nominal