User manual
4 PRG SERIES 400
®
400 AMP DISCONNECT USER MANUAL
Controls and Indicators
The S400 Disconnect contains the following connections and LED indicators.
Figure 1: Series 400 Disconnect Front Panel
FUSES
TUNGSTEN
MAIN BREAKER
S-400
400 AMP DISCONNECT
MODEL 23-9680-0200
For Use in Areas Not Readily Accessible by the General Public
WARNING - Risk of Electric Shock.
FOR USE BY QUALIFIED PERSONNEL ONLY
For use in Dry Locations
50 C Max Ambient
Type 1 Enclosure
Production Resource Group
8617 Ambassador Row
Made in USA
Suite 120
Dallas, TX 75247
XXXXX
CAN/CSA STD C22.2
No. 29
Certified to:
UL STD 1640
Conforms to:
INRUSH LIMIT
SETTING
LOADS
MIXED
LOADS
ARC
LOADS
OFF
3000A2000A 4000A
PUSH
TEST
TO
ON
POSITION TO
RESET BREAKER
SWITCH TO OFF
400 AMP
3ØY/30 A
120/208V
3ØY/30 A
120/208V
120/208V
3ØY/30 A
FOR BRANCH CIRCUIT USE ONLY
208V / 15A
120V / 15A
208V / 20A
NEUTRAL
GROUND
AGC1
1A / 250V
BREAKER
ON
MAIN
XØ VOLTS
YØ VOLTS
ZØ VOLTS
INPUT VOLTAGES
VOLTAGES
TEST POINT
XØ
XØ AMPS
NEUT AMPS
Ø -N
600A MAX
Ø -Ø
YØ
YØ AMPS
ZØ
OUTPUT
ZØ AMPS
400A MAX
Voltmeters - measures phase voltages
to ensure supply voltage is correct.
Pilot Light - indicates when Main
Breaker is ON. Provides a Push-To-Test
function.
Main Breaker - provides system
Inrush Limit Setting - adjustment
allows Inrush Limit to be set between
Current Meters - measures current
flowing in each phase and neutral
circuit.
2000 and 4000 Amps.
Voltmeter Rocker Switch - allows
connection of the meters between the
three phases (Ø-Ø) or between each
phase and neutral (Ø-N).
Test Points - to meter the output
voltages after the Main Breaker.
Convenience Outlet (2) - Edison style
receptacle, which provides power for
optional work lights, test equipment, etc.
L6-20 Power Outlet - provides 208V
power for a single luminaire.
Neutrik® Power Outlet (2) -
provides power for control consoles and
L21-30R Power Outlet (2) - provides
120/208V 30 Amp, 3-phase power.
protection.
support equipment.
Voltage input to the Cam-Loks is
measured before the breakers and will
show the input voltage even when the
Main Breaker is off.