PRG NODE PLUS USER MANUAL 7
INSTALLATION
System Options
Vx76
In the Vx76 configuration, one or two Vx76 control consoles may be connected to one or more PRG Node Plus units.
Guidelines:
+ When connecting two Vx76 consoles and multiple PRG Node Plus units, a 100Mb Ethernet switch or hub
must
be
used. Standard CAT5e Ethernet cables should be used in this configuration. Refer to the illustration below.
+ The Vx76 Mode of operation is used in this configuration. Refer to "Vx76 Mode" on page 16.
Figure 3: Vx76 Configuration Example
V676 CONSOLE "B"
PRG 7-PORT (COPPER) ETHERNETSWITCH
PRG 10-PORT (FIBER) ETHERNETSWITCH
* PRG Belden Ethernet cable or equivalent.
or
V676 CONSOLE "A"
CAT5e Ethernet Cables
PRG NODE PLUS
6x XLR DMX512 Data Cable
Art-Net DMX
(to S400 Rack)
Art-Net DMX
PRG NODE PLUS
6x XLR DMX512 Data Cable
(to S400 Rack)
100 Meter
Maximum
Vx76 Protocol CAT5e *
Vx76 Protocol CAT5e *