AC Line Current / Power vs. Voltage
Under-Voltage Lock-Out (UVLO)
Ballast UVLO = 135V/50Hz 170V to recover
24VDC LVS UVLO = 75V/50Hz 85V to recover
TEST VOLTS FREQ AMPS VA POWER PF
1 170 50Hz 12.53 2130 2124 0.997
2 180 50Hz 11.79 2122 2115 0.996
3 200 50Hz 10.56 2110 2100 0.995
4 200 60Hz 10.53 2106 2096 0.995
5 210 60Hz 10.01 2104 2091 0.994
6 220 50Hz 9.56 2103 2088 0.993
7 230 50Hz 9.13 2100 2083 0.992
8 240 50Hz 8.74 2098 2080 0.990
9 240 60Hz 8.74 2098 2078 0.990
10 250 50Hz 8.38 2095 2074 0.989
11 260 50Hz 8.06 2093 2065 0.986
12 270 50Hz 9.09 2455 2059 0.838
13 270 60Hz 9.08 2449 2065 0.841