User's Manual

40
41
Controls &
Connections
Recording
Tutorials
Technical
Information
Multiple
Mixers
Overview
2 Controls & Connections
2.6 The Aux Bus
2.6.2 Internal Effects Send Controls
Mute Button
Mutes and Unmutes the Internal Effects Bus.
This button will mute or unmute its internal effects (EFX)
bus. It will illuminate red when the bus is muted.
Post Fader Send Button
Enables and Disables Post Fader Send.
By default, this button is enabled, and the send levels
to the effects buses are post-EQ, post-dynamics
processing, and post-fader, and therefore are affected
by fader settings. If the button is disabled, by default,
the EFX sends use the Pre 2 setting, in which the sends
are post-EQ and post-dynamics but pre-fader. However,
in the System Menu, you can switch the EFX sends to
the Pre 1 setting, in which the sends are pre-Fat Channel
dynamics processing and EQ and pre-fader. Please
review Section 2.10.4 for details.
Output Level Control
Adjusts the Master Level of the Effects Send.
This knob adjusts the master level of the internal effects
send.
Internal Effects Send
Select Button
Enables Fat Channel Viewing.
As described in section 2.3.1, the Select button routes
its aux send through the Fat Channel allowing you to add
dynamics processing and EQ, as well as routing the aux
send to outputs.
Mix Button
Enables Aux Bus Mixing and Metering in the Fat
Channel.
When this button is enabled, the 16 encoders in the Fat
Channel become the aux-send level controls for each of
their respective input channels. The meters will display
the send level of each of the input channels.