PDF

Cascode Charge Balance During ZVS Turn-ON
Improper charge balance
results in loss of ZVS
Significant energy loss
Properly balanced Cascode
achieves full ZVS
No energy loss
APEC 2015 Seminar S17
63
I
L
V
sw
V
DS-Si
X. Huang, W. Du, Z. Liu, F. C. Lee, and Q. Li, “Performance
Analysis of Cascode GaN Device,” CPES Review, Nov 18, 2013
Measured Results: IR-Infineon Cascode