INSTALLATION INSTRUCTIONS P5080T Universal Low Profile Tilt Mount for 50” to 80” Flat Panels NORTH AMERICA 3130 East Miraloma Avenue Anaheim, CA 92806 USA USA and Canada Phone: 1-800-368-9700 Fax: 1-800-832-4888 Other Locations Phone: (001)-714-632-7100 Fax: (001)-714-632-1044 EUROPE Swallow House, Shilton Industrial Estate, Shilton, Coventry, England CV79JY Phone: +44 (0) 2476 614700 Fax: +44 (0) 2476 614710 9531-208-F01-06
P5080T Contents Weight Limit................................................................................................................................................................................... 2 Warning Statements...................................................................................................................................................................... 2 Installation Tools................................................................................................
P5080T Installation Tools The following tools may be required depending upon your particular installation. They are not included. ¼˝ Drill Bit for Wood Stud Electronic Stud Finder 7/16˝ Drill Bit for Steel Stud* /16˝ Concrete Drill Bit** Hand Held Drill 5 2 1 Pencil Level Protective Eyewear Socket Wrench Tape Measure ½˝ Socket Hammer** Phillips Tip Screwdriver M10 Socket* * Optional tools for steel stud installations. ** Optional tools for concrete installations.
P5080T Parts List (cont’d) Mounting Hardware M4 x 16mm Screw (Qty 6) M8 x 16mm Screw (Qty 6) M4 x 25mm Screw (Qty 6) M8 x 25mm Screw (Qty 6) M4 x 30mm Screw (Qty 6) M8 x 30mm Screw (Qty 6) M5 x 16mm Screw (Qty 6) M8 x 45mm Screw (Qty 6) M5 x 25mm Screw (Qty 6) M5 x 30mm Screw (Qty 6) M8 x 70mm Screw (Qty 4) M10 x 30mm Screw (Qty 6) M6 x 16mm Screw (Qty 6) M6 x 25mm Screw (Qty 6) M6 x 30mm Screw (Qty 6) M6 x 45mm Screw (Qty 6) Page 4 Visit the Premier Mounts website at http://www.
P5080T Features Leveling Screws Allows for leveling adjustments of the flat panel after mounting. Cable/Electrical Cut Out A large cutout on the wall plate allows for easy cable access and power distribution installations. Directional Mounting Arrow The arrow lets you know which edge is up. Low Profile Design Holds the flat panel less than 2” from the wall. Mounting Slots Allow for a variety of stud configurations and lateral shift adjustments when mounting your flat panel.
P5080T Installing the Wall Plate Introduction Directional Mounting Arrow The Directional Mounting Arrow stamped into the top of the P5080T wall mount indicates which edge is the top. Mounting Safety Two people are recommended to install this mount. Determining the Mounting Surface If you will be installing your P5080T mount to wood studs, proceed to the “Wood Stud Installation” section. If you will be installing your P5080T mount to a concrete wall, proceed to the “Concrete Installation” section.
P5080T Installing the Wall Plate (cont’d) Step 3 Drill a “pilot hole” in the center of the upper-right mark using a ¼″ drill bit and power drill. Only use a ¼″ drill bit when drilling the pilot holes. Step 4 Place the wall plate against the wall and align it with ®® the pilot hole. Insert one (1) 5/16″ x 3″ lag bolt and one (1) 5/16″ washer into the upper right mounting hole and tighten using a socket wrench and ½″ socket. Do not overtighten the lag bolt. Step 5 Level the wall plate.
P5080T Installing the Wall Plate (cont’d) Step 7 Insert one (1) ®® /16″ x 3″ lag bolt and one (1) 5/16″ washer into each pilot hole. Tighten all lag bolts using a socket wrench and ½″ socket. 5 Do not overtighten the lag bolts when attaching the mount to the wall. Improper installation may result in personal injury or property damage. Proceed to the “Installing the Mounting Bracket” section. Concrete Installation The supplied 5/16″ concrete wedge anchors must be used for concrete installation.
P5080T Installing the Wall Plate (cont’d) Step 3 Insert a concrete wedge anchor into each hole. ®® If necessary, lightly tap each concrete wedge anchor into place with a hammer. Remove the nuts and washers from all six (6) concrete wedge anchors. Step 4 Place the wall plate against the wall over the ®® ¯¯ threaded shafts of the concrete wedge anchors. Replace the washers which you removed from the concrete wedge anchors with the 5/16″ washers shown in the parts list on Page 3.
Installing the Wall Plate (cont’d) P5080T Step 2 Place the wall plate against the wall in the desired ®® ¯¯ °° ±± viewing location. Adjust the wall plate to match the locations of the steel studs. Level the wall plate. Use a pencil and mark 3 upper and 3 lower locations where you will be drilling holes for the steel stud anchors. Set the wall plate to one side in a safe location. Step 3 Use a power drill and ®® 7 /16″ drill bit to drill a hole at each of the marks.
P5080T Installing the Wall Plate (cont’d) Step 5 Align the wall plate over the steel stud anchor sleeves. ®® Insert a steel stud anchor screw and a / ″ washer into 5 ¯¯ 16 each steel stud anchor sleeve. Use a Phillips screwdriver and tighten each steel stud anchor screw until it is snug. Do not overtighten the steel stud anchor screws. Do not use a power drill to tighten the steel stud anchor screws. Proceed to the “Installing the Mounting Bracket” section.
P5080T Installing the Mounting Bracket (cont’d) Universal Washer Installation Premier Mounts’ Universal Washers are designed to accommodate the various M4, M5, M6 and M8 hole sizes required by flat panels. M8 M5, M6 M4 Do not place excessive pressure on the back of the flat panel, as this may damage your flat panel. The Universal Washer must be installed between the head of the mounting screw and the mounting bracket as shown.
P5080T Installing the Mounting Bracket (cont’d) Locking Screw Installation You must install the locking screws before you attach the mounting bracket to the back of the flat panel. The locking screws consists of two (2) M6 x 120mm screws. Thread one (1) locking screw into the bottom mounting hole on each of the mounting brackets. Make sure the locking screw is securely threaded into the mounting tab before proceeding. Do not thread the locking screw any further once it is even with the mounting tab.
Attaching the Mounting Bracket to the Flat Panel P5080T This section assumes that you have read and understood these sections: ●● Selecting the Proper Mounting Hardware ●● Universal Washer Installation ●● Universal Spacer Installation Place your flat panel screen-side down on a soft, flat ®® ¯¯ °° surface. Identify the number and location of the thread inserts on the back of your flat panel. Align the holes on each mounting bracket with the thread inserts on the back of your flat panel.
P5080T Mounting Bracket Adjustments Leveling Screw Adjustment If your flat panel is tilted too far to one side, the leveling screws will allow you to compensate for this tilt by adjusting the screws with a screwdriver. Loosen both locking screws. ®® Adjust the tilt of your flat panel. ¯¯ Tighten both locking screws. M6 x 30mm Leveling Screw (1 per Bracket) Caution! It is possible to dislodge your flat panel while you level your flat panel. Use extreme caution until you tighten the locking screws.
P5080T Utilizing the Security Barrel Your P5080T Mount includes one (1) Security Barrel and one (1) Lock-It™ Security Tube which can provide additional theft deterrence for your flat panel. PCB-CSL1 Security Cable Thread the cable through the hole on the security barrel. Attach the PCB-CSL1 locking mechanism and secure it using the supplied key. Padlock Place the locking hook through the hole of the security barrel. Snap lock and locking hook together.
P5080T Warranty PREMIER MOUNTS LIMITED LIFETIME WARRANTY What and Who is Covered by this Limited Warranty and for How Long Premier Mounts warrants this product to be free from defects in material and workmanship for the lifetime of the original owner of this product. The limited warranty is valid only for the original purchaser of the product. What Premier Mounts Will Do At the sole option of Premier Mounts, Premier Mounts will repair or replace any product or product part that is defective.