INSTALLATION INSTRUCTIONS Universal Tilt Wall Mount Model: CTM-MS4 NORTH AMERICA 3130 East Miraloma Avenue Anaheim, CA 92806 USA USA and Canada Phone: 1.800.368.9700 Fax: 1.800.832.4888 Other Locations Phone: (001).714.632.7100 Fax: (001).714.632.
CTM-MS4 Table of Contents Warning Statements ........................................................................................................................................- 3 Parts List ...........................................................................................................................................................- 4 Installation Tools .........................................................................................................................................
CTM-MS4 Warning Statements PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY PREMIER MOUNTS PRODUCT FOR PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY UNAUTHORIZED ATTACHMENTS OR MODIFICATIONS, AND IS NOT RESPONSIBLE FOR ANY DAMAGES, CLAIMS, DEMANDS, SUITS, ACTIONS OR CAUSES OF ACTION OF WHATEVER KIND RESULTING FROM, ARISING OUT OF OR IN ANY MANNER RELATING TO ANY SUCH USE, ATTACHMENTS OR MODIFICATIONS. THE WALL STRUCTURE MUST BE CAPABLE OF SUPPORTING 300 LBS.
CTM-MS4 Parts List NOTE: This wall mount is shipped with all proper installation hardware and components. Make sure that none of these parts are missing and/or damaged before beginning installation. If there are parts missing and/or damaged, please stop the installation and contact Premier Mounts (800-368-9700).
CTM-MS4 M5 x 25 (Qty 8) M5 x 30 M6 x 20 M6 x 25 M6 x 30 (Qty 8) (Qty 8) (Qty 8) (Qty 8) (Qty 8) M6 x 35 (Qty 8) M8 x 20 (Qty 8) M8 x 25 (Qty 8) M8 x 30 M8 x 35 (Qty 8) (Qty 4) M8 x 70 Nylon spacers and flat washers’ actual size NOTE: The nylon spacers may be stacked to achieve proper spacing.
CTM-MS4 How to Determine the Correct Spacer 1. The following illustration shows a display mounting surface that will not need the use of a spacer. 2. The illustration shows a display mounting surface that will need a spacer to correctly install the mounting plate. Anytime a display has a recessed mounting point, a spacer must be used. Select the spacer(s) that will create a flush and level mounting surface for the mounting plate. 3. 4. 5.
CTM-MS4 Thread Depth Indicator 1. 2. 3. 4. Insert the thread depth indicator (supplied) through the thread inserts found on the back of the flat panel to make sure the inserts measure the same full depth and mark it (Figure 1). Locate the correct diameter screw for the thread insert. Compare your marking to the screws (supplied). If your selected screw is longer than the marking on the thread depth indicator, DO NOT USE this screw. The screw length must not bypass the marking.
CTM-MS4 Mounting Bracket Installation NOTE: Proper installation procedure by qualified personnel as outlined in the installation instructions must be adhered to. Failure to do so could result in serious personal injury and possible damage to the flat panel. WARNING: 1. 2. INVERT THE FLAT PANEL PLACE IT ON A SOFT, FLAT SUFRACE TO PREVENT DAMAGE TO THE FLAT PANEL. USE A BLANKET, FOAM, ETC. FAILURE TO DO SO WILL RESULT IN DAMAGING THE FLAT PANEL.
CTM-MS4 3. 4. Install the nylon spacers (if needed) to the mounting points on the flat panel (Figure 6). Lay the mounting brackets (stamped arrows facing out) - (Figure 7). Nylon Spacers, If Applicable Bottom of Flat Panel Notched Cut Outs Center Mark Figure 6 Inverted Flat Panel Arrows Facing Out Figure 7 5. 6. Match the center of viewing guide with the centerline you marked in Step 1 (Figure 8). The mounting brackets are designed with a center of viewing guide on the outside (Figure 9).
CTM-MS4 Mounting Bracket Notched Cut Out Figure 8 Bottom of the Flat Panel Figure 9 7. 8. The Griplate™ has M4, M5 M6 and M8 hole patterns to fit the hardware that your flat panel requires. EXAMPLE: If your plasma uses M8 x 20 Phillip screws, use the M8 mounting points (Figure 10). Once the mounting brackets are aligned, secure the Griplate™ to the flat panel. Use (1) Griplate™ per mounting point (Figure 11).
CTM-MS4 CTM-MS4 Installation 1. 2. 3. Using a (commercially available) wood stud finder, locate the 16" or 24" stud centers behind the wall (Figure 12). Once found, make a pencil marking on the center of the wood studs (Figure 13). Place the wall plate to the reference line and mark the lag bolt mounting points through the wall plate slots on the wall (see NOTE below). Mark the wall and the center of the wood studs.
CTM-MS4 4. Use a screwdriver to remove the lower mounting rod screw. 5. Once the mounting rod screw is removed, insert one (1) 1 ¼˝ set screw. 6. Once the mounting rod set screw has been inserted into the first wall plate, place the second wall plate next to the first wall plate. Line up the mounting hole with the mounting rod set screw and then slide the two wall plates together. Slide the mounting rod onto the wall plate set screw and slowly thread the rod onto the set screw until tight. 9.
CTM-MS4 11. 12. 13. Level the wall plate with the reference arrow pointing up to the ceiling (Figure 15). Drill ¼" pilot holes to the marked wall. Secure the plate using the 5/16" lag bolts and flat washers (Figure 16). Mark the mounting slot openings 16" Wall Plates Figure 15 Wall Plate Figure 16.
CTM-MS4 Installing the Flat Panel Display (CTM-MS4) WARNING: 1. AT LEAST TWO QUALIFIED PERSONNEL ARE STRONGLY RECOMMENDED FOR INSTALLATION OF THIS PRODUCT. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL. Raise the flat panel with the mounting brackets secured to the flat panel and insert the top hooks over the upper rod. The lower hooks should rest on the lower rod (Figure 17).
CTM-MS4 2. Make any lateral shift adjustment and lock it by tightening the screws found on the bottom of the mounting brackets. CAUTION: NOTE: Do not over tighten the screws to the rods (Figure 18). To remove the display from the wall simply loosen the screws using a Phillips screwdriver and lift the unit of the wall carefully.
CTM-MS4 3. Tilt the flat panel and secure the safety knobs to each of the mounting brackets (Figure 19). NOTE: To remove the display from the wall simply extend the display to its maximum tilt range, remove the safety knobs, push the flat panel back to it’s flat position, loosen or remove the lateral shift screws and lift the unit off the wall.
CTM-MS4 Technical Specifications Figure 20 Installation Manual Page 17
CTM-MS4 Warranty Limited Lifetime Warranty All Premier Mounts products carry a limited lifetime warranty from ship date against defects in materials and workmanship. Premier Mounts is not liable for improper installation that results in damage to mounts, adapters, display equipment or personal injury. DISCLAIMER OF WARRANTY.