Owner's Manual

SYSTEM REQUIREMENTS
Your chosen installation location and water supply must meet ALL of the following
requirements:
20-90 PSI (1.38-6.20BAR)
34-110°F (1.1-43.3°C)
System must be protected from freezing
Firm level surface AFTER the pressure tank
3-prong, 120V outlet within 5 ft. (1.5 m) of the control head with constant
power. GFCI outlet is recommended. Use of an extension cord is NOT
recommended.
A 1.5-inch standpipe, sump pit, or outside drain. Please note: The drain line
is pressurized and can be ran vertically if necessary.
1. VERIFY SYSTEM INVENTORY
Use the following table to help verify the parts that are included with your system
and verify that they are all accounted for. Inspect all parts for damage and report
any damage immediately. Damage claims must be made within 7 days of
delivery to be eligible for replacement.
Depending on system size you can see what tank size and media amounts you will
receive:
System Size
0.5 ft³
0.75 ft³
1 ft³
1.5 ft³
2 ft³
2.5 ft³
3 ft³
Tank (in
inches)
8 x 44
8 x 44
9 x 48
10 x 54
12 x 52
13 x 54
14 x 65
Gravel/Garnet
10 lb.
10 lb.
12 lb.
16 lb.
20 lb.
35 lb.
50 lb.
Media
0.5 ft³
0.75 ft³
1 ft³
1.5 ft³
2 ft³
2.5 ft³
3 ft³
Tank Size and Media Qty