Owner's Manual
Table Of Contents
- Installation Instructions for Backwashing Systems with Fleck 5600 and 5600SXT
- Thank You
- Before You Begin
- Basic plumbing skills are required for installation. If you are unsure of your abilities to install the system using these instructions please hire a qualified plumber.
- Read through your parts list and verify all components are accounted for and in good condition BEFORE scheduling a plumber.
- Please read through the entire instruction manual carefully. If hiring a plumber ensure they have a copy before they start.
- Most common questions are answered in the instructions or FAQ section. If you have read both of those and still have questions you may contact us for further help.
- Plumbing related questions need to be directed to a locally qualified plumber. We are not plumbers and any plumbing questions we receive will not be answered.
- System Requirements
- Before you start plumbing
- Plumbing the system in
- Frequently Asked Questions
SXT Error Codes
Error
Code
Error Type
Cause
Solution
0
Cam
Sense
Error
Piston took more
than 6 minutes to
advance
Unplug the system, disconnect the piston from the motor/gear, and
verify that the piston moves freely inside the valve; if it does not
replacement of the seal and spacers and possibly the piston is
required. After reconnecting the piston, inspect the control head
for any broken, worn, or disconnected parts, and replace or
reconnect any that are found. Perform a hard reset. After verifying
programming run the system through a backwash and watch the
motor to ensure that it is moving the piston, if it is not the motor
needs to be replaced. If error still occurs contact us for support.
1
Cycle
Step Error
Unexpected cycle
input
Unplug the system and check to ensure all electrical connections
and cam switches are secure. Plug the unit back in and check the
master programming and ensure valve type and system type are
correct for your system. Initiate a manual regeneration and verify it
progresses through the steps correctly. If error reoccurs, contact us
for support.
2
Regen
Failure
More than 99 days
since last backwash
(7 on day of the
week setups)
Perform a manual backwash to reset the error. Check your settings
to ensure the system is setup to backwash automatically. Check the
meter to ensure it is not stuck and that the gallons remaining is
counting down.
3
Memory
Error
Circuit board
memory failure
Perform a hard reset and go through the master programming to
update the settings. If error occurs again contact us for support
UD
Upper
Drive
Sync
Piston is syncing
Common when changing programming or if system looses power.
System will automatically recover from this state.