Owner's Manual

DO
Day Override
3
This setting will start the backwash cycle after the set number of days. Typically set to 3 or
less to ensure the media gets lifted and cleaned off regularly. This ensures effective
filtration and long media life. If you have very dirty water or use large volumes of water you
will want to set this to 1 or 2.
RT
Regen Time
12:00
This sets the time that the backwash cycle will start. This process can take up to 2 hours
depending on system size and configuration, so schedule it when water will not be used. It
is common to set to run when everyone is asleep or out of the house, and ensure it does
not conflict with any other systems you may have.
BW
Backwash
10
This sets the length of the backwash portion of the cycle. During this cycle water flows
through the system in reverse to lift the media and rinse off accumulated contaminants,
with a strong flow of water going out the drain line. Reducing this cycle can lead to reduced
media life and premature system failure. For very dirty water longer times may be needed.
BD
Brine Draw
N/A
This sets the length of the brine draw portion of the cycle. Standard backwashing systems
do not use this setting and typically it will not show.
RR
Rapid Rinse
10
The rapid rinse cycle runs water through the tank in the normal direction to settle the
media for normal operation. During this cycle there will be a steady flow of water down the
drain.
BF
Brine Fill
N/A
This sets the length of the brine fill portion of the cycle. Standard backwashing systems do
not use this setting and typically it will not show.
D1-D7
Day of the
Week Setting
OFF
Set to On or OFF for each day of the week. Only applies to systems with Control Type day,
not typically used.
CD
Current Day
1-7
Used to set the current day. Only applies to systems with Control Type day, not typically
used.
FM
Flow Meter
Type
(metered
systems only)
P0.7
3/4" Paddle Wheel Meter
Gen
Generic or Other Meter
P2.0
2" Paddle Wheel Meter
t1.5
1.5" Turbine Meter
P1.5
1.5" Paddle Wheel Meter
t1.2
1.2" Turbine Meter
t1.0
1" Turbine Meter
P1.0
1" Paddle Wheel Meter
t0.7
3/4" Turbine Meter
K
Meter Pulse
Setting
0.1-999.9
Pulses per gallon. Only applies to systems with FM set to Gen, not typically used.
Pressing the extra cycle button after the final setting will save your changes. If no buttons are pressed for 60 seconds while in
programming mode the changes will be cancelled.
If you accidentally change a setting that does not have a recommended or variable value: Please do a hard reset as outlined in
the resets section to return all values to default. You can then go back through the programming to set it up according the the
chart above.
SXT Master Programming Chart
Once you have finished programming use the arrows to set the current time of day. Once the
time is set the display should then show the service icon, with the data display flashing
between the current time of day and days remaining until the next backwash. Once it reaches
0 the system will queue a backwash for the set time. A flashing service icon indicates that a
backwash is queued. A manual backwash can be queued by pressing the extra cycle button. An
immediate backwash can be initiated by holding the extra cycle button for about 5
seconds. The service icon indicates that the system is "In Service" and functioning correctly,
it does NOT mean that the system needs service.