INSTALLATION INSTRUCTIONS PCM-MS3 Universal Flat Panel Mount NORTH AMERICA 3130 East Miraloma Avenue Anaheim, CA 92806 USA USA and Canada – Phone: 800-368-9700 Fax: 800-832-4888 EUROPE Swallow House, Shilton Industrial Estate, Shilton, Coventry, England CV79JY Phone: +44 (0) 2476 614700 Fax: +44 (0) 2476 614710 Other Locations – Phone: (001)-714-632-7100; Fax: (001)-714-632-1044 ©Premier Mounts 2008 9531-099-001-02 AUSTRALIA, NEW ZEALAND, OCEANIA (DISTRIBUTOR) P.O.
PCM-MS3 Table of Contents Warning Statements Parts List Installation Tools Thread Depth Indicator Mount Orientation Securing the Mounting Brackets Marking the Wall Lower Mounting Points PCM-MS3 Installation Securing the Display Lateral Shift Adjustment Safety Knurl Knob Installation Technical Specififcations Warranty 2 3 3 6 7 8 9 9 10 11 11 11 12 13 Warning Statements PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY PREMIER MOUNTS PRODUCT FOR PURPOSES OTHER THAN THOSE FOR WHICH IT
PCM-MS3 Parts List This wall mount is shipped with all proper installation hardware and components. Make sure that none of these parts are missing and/or damaged before beginning installation. If there are parts missing and/or damaged, please stop the installation and contact Premier Mounts (800-368-9700).
PCM-MS3 M4 x 16 (Qty 8) M6 x 30 (Qty 8) (Qty 8) M4 x 25 (Qty 8) M6 x 45 M5 x 12 M5 x 16 M5 x 20 (Qty 8) M8 x 20 (Qty 8) (Qty 8) M8 x 25 (Qty 8) (Qty 8) (Qty 8) M5 x 25 M8 x 30 (Qty 8) M5 x 50 (Qty 8) M6 x 16 M6 x 20 (Qty 8) (Qty 8) M8 x 35 M8 x 45 M8 x 70 Page 4 (Qty 8) (Qty 8) (Qty 4) Installation Instructions
PCM-MS3 The nylon spacers may be stacked to achieve proper spacing.
PCM-MS3 Thread Depth Indicator 1. Insert the thread depth indicator (supplied) through the thread inserts found on the back of the flat panel to make sure the inserts measure the same full depth and mark it (Figure 1). 2. Locate the correct diameter screw for the thread insert. Compare your marking to the screws (supplied). 3. If your selected screw is longer than the marking on the thread depth indicator, DO NOT USE this screw. 4. The screw length must not bypass the marking.
PCM-MS3 Mount Orientation Proper installation procedure by qualified personnel as outlined in the installation instructions must be adhered to. Failure to do so could result in serious personal injury and possible damage to the flat panel. Invert the flat panel place it on a soft, flat surface to prevent damage to the flat panel. Use a blanket, foam, etc. Failure to do so will result in damaging the flat panel. Do not lay the flat panel on the floor without any protection to the glass.
PCM-MS3 Display CL Align the Mounting Brackets Mounting Bracket Viewing Guide Center Line Step 3. Match the center of viewing guide with the enter line you marked in step 1. Step 4. The mounting brackets are designed with a center of viewing guide on the side of them. Securing the Mounting Brackets Dimples Screwdriver M8 M6 M5 M4 Dimples Facing Up Dimples Facing Up Dimples Facing Down The Griplate™ have M4, M5 M6 and M8 hole patterns to fit the hardware that your flat panel requires.
PCM-MS3 Marking the Wall Viewing Port Wall Marking Wall Structutre Center Line Mark Bottom of Template Viewing Port Step 1. Align the center viewing port from the carton template to the wall. Step 2. Match the center of viewing port to the center of viewing height desired. Step 3. Mark a line on the bottom of the carton template. Lower Mounting Points Wall Plate Level Wall Structutre Center Line Step 1.
PCM-MS3 PCM-MS3 Installation Lower Mounting Plate Level Wa l l Plate Template Wall Plate Lag Bolt and Washer Step 1. Level and secure the plate to the wall with the reference arrow facing up to the ceiling. Step 2. Secure the plate using six (6) 5/16” x 3” lag bolts and six (6) 5/16 flat washers. Step 3. When the bottom wall plate is properly installed to the wall, place the carton template on top of the wall plate. Step 4.
PCM-MS3 Securing the Display Wall Plate Step 1. Raise the flat panel with the mounting brackets secured to the flat panel and insert the top and bottom hooks from each bracket to the rods from the wall plates. Top Bottom Lateral Shift Adjustment Step 1. Make any lateral shift adjustment and lock it by tightening the two (2) M6 x 30 (mm) Phillips screws found on the bottom of the mounting brackets. Do not over tighten the M6 screws to the rods.
PCM-MS3 Technical Specifications All measurements are in inches(mm) Page 12 Installation Instructions
PCM-MS3 Warranty PREMIER MOUNTS LIMITED LIFETIME WARRANTY What and Who is Covered by this Limited Warranty and for How Long Premier Mounts warrants this product to be free from defects in material and workmanship for the lifetime of the original owner of this product. The limited warranty is valid only for the original purchaser of the product. What Premier Mounts Will Do At the sole option of Premier Mounts, Premier Mounts will repair or replace any product or product part that is defective.
PCM-MS3 Page 14 Installation Instructions