INSTALLATION INSTRUCTIONS PCM-MS2 Universal Flat Panel Mount NORTH AMERICA EUROPE 3130 East Miraloma Avenue Swallow House, Anaheim, CA 92806 USA Shilton Industrial Estate, USA and Canada – Shilton, Coventry, England CV79JY Phone: 800-368-9700 Phone: +44 (0) 2476 614700 Fax: +44 (0) 2476 614710 Fax: 800-832-4888 Other Locations – Phone: (001)-714-632-7100; Fax: (001)-714-632-1044 ©Premier Mounts 2008 9531-000-501-03 AUSTRALIA, NEW ZEALAND, OCEANIA (DISTRIBUTOR) P.O.
PCM-MS2 Table of Contents Warning Statements ...........................................................................................................................................- 2 Parts List ............................................................................................................................................................- 3 Installation Tools .....................................................................................................................................
PCM-MS2 Parts List This wall mount is shipped with all proper installation hardware and components. Make sure that none of these parts are missing and/or damaged before beginning installation. If there are parts missing and/or damaged, please stop the installation and contact Premier Mounts (800-368-9700).
PCM-MS2 M4 x 16 M4 x 25 M5 x 12 M5 x 16 M5 x 20 (Qty 8) M6 x 20 (Qty 6) M8 x 20 (Qty 6) (Qty 4) (Qty 8) (Qty 6) M8 x 25 (Qty 6) M8 x 30 M5 x 25 Installation Manual (Qty 6) (Qty 4) M5 x 50 M6 x 12 (Qty 6) (Qty 4) M8 x 35 (Qty 8) M8 x 70 (Qty 4) (Qty 4) Page - 4 -
PCM-MS2 Nylon spacers and flat washers NOTE: The nylon spacers may be stacked to achieve proper spacing.
PCM-MS2 Thread Depth Indicator 1. Insert the thread depth indicator (supplied) through the thread inserts found on the back of the flat panel to make sure the inserts measure the same full depth and mark it. 2. Locate the correct diameter screw for the thread insert. Compare your marking to the screws (supplied). 3. If your selected screw is longer than the marking on the thread depth indicator, DO NOT USE this screw. 4. The screw length must not bypass the marking.
PCM-MS2 Finding the Center of the Plasma Display Proper installation procedure by qualified personnel as outlined in the installation instructions must be adhered to. Failure to do so could result in serious personal injury and possible damage to the flat panel. Invert the flat panel place it on a soft, flat surface to prevent damage to the flat panel. Use a blanket, foam, etc. Failure to do so will result in damaging the flat panel.
PCM-MS2 Positioning the Mounting Brackets If your display has uneven mounting points, or recessed mounting points, please use the provided spacers (Page 5). Step 1. Install the nylon spacers to the mounting points on the flat panel. If the nylon spacers apply to your flat panel, please see Page 5. Step 2. Lay the left and right mounting brackets (stamped arrows facing out).
PCM-MS2 Step 3. Match the center of viewing guide with the center line you marked in step 1. Step 4. The mounting brackets are designed with a center of viewing guide on the side of them.
PCM-MS2 Securing the Mounting Brackets The Griplate™ have M4, M5 M6 and M8 hole patterns to fit the hardware that your flat panel requires. EXAMPLE: If your plasma uses M8 x 20 Phillip screws, use the M8 mounting points. Step 1. Pre-install two (2) M6 x 30 (mm) Phillip pan screws to the bottom of the left and right hand side mounting brackets. Step 2. Once the mounting brackets are aligned secure the Griplate™ to the flat panel.
PCM-MS2 Marking the Wall Step 1. Align the center viewing port from the carton template to the wall. Step 2. Match the center of viewing port to the center of viewing height desired. Step 3. Mark a line on the bottom of the carton template.
PCM-MS2 Marking the Bottom Plate Mounting Points Step 1. Place the upper portion of the bottom wall plate to the reference line and mark the four (4) lag bolt mounting points through the wall plate slots on the wall. Step 2. Level the wall plate with the reference arrow pointing up to the ceiling. Step 3. Pilot holes are recommended, size will depend on the commercially available hardware that will be used.
PCM-MS2 Securing the Bottom Wall Plate Step 1. Level and secure the plate to the wall with the reference arrow facing up to the ceiling. Step 2. Secure the plate using (commercially available) suitable hardware depending on your installation environment. Do not over tighten the mounting hardware. Step 3. When the bottom wall plate is properly installed to the wall. Lay the carton template on top of the wall plate. Step 4.
PCM-MS2 Securing the Top Plate Step 1. Drill four (4) ¼" pilot holes to the marked Step 2. Level and secure the plate to the wall with the reference arrow facing up to the ceiling. Step 3. Secure the plate using (commercially available) suitable hardware depending on your installation environment. Do not over tighten the mounting hardware. Check the mount for proper tightness and security.
PCM-MS2 Securing the Plasma to the Wall Mount AT LEAST (2) QUALIFIED PERSONNEL ARE STRONGLY RECOMMENDED FOR INSTALLATION OF THIS PRODUCT. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL. Step 1. Raise the flat panel with the mounting brackets secured to the flat panel and insert the top and bottom hooks from each bracket to the rods from the wall plates. Step 2.
PCM-MS2 Lateral shift adjustment Step 1. Tilt the flat panel and secure the two (2) M6 x 12 mm) safety knobs to each of the mounting brackets. To remove the display from the wall simply extend the display to its maximum tilt range, remove the two 6 (mm) safety knurl knobs push the flat panel back to it’s flat position loosen or remove the two (2) M6 x 30 lateral shift screws and lift the unit of the wall.
PCM-MS2 Technical Specifications All measurements are in inches(mm).
PCM-MS2 Warranty PREMIER MOUNTS LIMITED LIFETIME WARRANTY What and Who is Covered by this Limited Warranty and for How Long Premier Mounts warrants this product to be free from defects in material and workmanship for the lifetime of the original owner of this product. The limited warranty is valid only for the original purchaser of the product. What Premier Mounts Will Do At the sole option of Premier Mounts, Premier Mounts will repair or replace any product or product part that is defective.