INSTALLATION MANUAL CTM-MS2 Premier Mounts 3130 E. Miraloma Avenue Anaheim, CA 92806 Phone: (800) 368-9700 Fax: (800) 832-4888 mounts@mounts.com www.mounts.com IN-CTMMS2.
PBL-110 Projector Mount Page - 2 - Installation Manual
CTM-MS2 Table of Contents Warning Statements ........................................................................................................................................- 4 Parts List ...........................................................................................................................................................- 5 Installation Tools .........................................................................................................................................
CTM-MS2 Warning Statements WARNING: THE WALL STRUCTURE MUST BE CAPABLE OF SUPPORTING 160 LBS. IF NOT, THE WALL STRUCTURE MUST BE REINFORCED. PROPER INSTALLATION PROCEDURE BY A QUALIFIED SERVICE TECHNICIAN, AS OUTLINED IN THE INSTALLATION INSTRUCTIONS, MUST BE ADHERED TO. FAILURE TO DO SO COULD RESULT IN SERIOUS PERSONAL INJURY, OR EVEN DEATH. WARNING: SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE INSTALLATION OF THIS PRODUCT.
CTM-MS2 Parts List NOTE: This wall mount is shipped with all proper installation hardware and components. Make sure that none of these parts are missing and/or damaged before beginning installation. If there are parts missing and/or damaged, please stop the installation and contact Premier Mounts (800-368-9700).
CTM-MS2 M4 x 16 (Qty 8) M6 x 20 (Qty 6) (Qty 4) M4 x 25 (Qty 2) M6 x 30 M5 x 12 M5 x 16 M5 x 20 (Qty 8) M8 x 20 (Qty 6) (Qty 6) M8 x 25 M8 x 30 M5 x 50 (Qty 6) (Qty 4) (Qty 8) M8 x 35 M8 x 70 Page - 6 - (Qty 6) (Qty 4) M5 x 25 M6 x 12 (Qty 6) (Qty 4) (Qty 4) Installation Manual
CTM-MS2 Nylon spacers and flat washers actual size NOTE: The nylon spacers may be stacked to achieve proper spacing.
CTM-MS2 Thread Depth Indicator 1. 2. 3. 4. Insert the thread depth indicator (supplied) through the thread inserts found on the back of the flat panel to make sure the inserts measure the same full depth and mark it (Figure 1). Locate the correct diameter screw for the thread insert. Compare your marking to the screws (supplied). If your selected screw is longer than the marking on the thread depth indicator, DO NOT USE this screw. The screw length must not bypass the marking.
CTM-MS2 Mounting Bracket Installation NOTE: Proper installation procedure by qualified personnel as outlined in the installation instructions must be adhered to. Failure to do so could result in serious personal injury and possible damage to the flat panel. WARNING: 1. 2. INVERT THE FLAT PANEL PLACE IT ON A SOFT, FLAT SUFRACE TO PREVENT DAMAGE TO THE FLAT PANEL. USE A BLANKET, FOAM, ETC. FAILURE TO DO SO WILL RESULT IN DAMAGING THE FLAT PANEL.
CTM-MS2 3. 4. Install the nylon spacers (if needed) to the mounting points on the flat panel (Figure 6). Lay the left and right mounting brackets (stamped arrows facing out) - (Figure 7). Nylon Spacers, If Applicable Center Mark Mounting Brackets Inverted Flat Panel Bottom of Flat Panel Arrows Facing Out Figure 6 5. 6. Figure 7 Match the center of viewing guide with the centerline you marked in Step 1 (Figure 8).
CTM-MS2 Mounting Bracket CL Bottom of Flat Panel Center of Viewing Guide 7. 8. Center of Flat Panel Bottom of the Flat Panel Align the Mounting Brackets Figure 8 Figure 9 The Griplates™ have M4, M5 M6 and M8 hole patterns to fit the hardware that your flat panel requires. EXAMPLE: If your plasma uses M8 x 20 Phillip screws. Use the M8 mounting points (Figure 10). Once the mounting brackets are aligned secure the Griplate™ to the flat panel. Use (1) Griplate™ per mounting point (Figure 11).
CTM-MS2 CTM-MS2 Installation 1. Using a (commercially available) wood stud finder, locate the 16" or 24" stud centers behind the wall (Figure 12). 2. Once found, make a pencil marking on the center of the wood studs (Figure 13). NOTE: The wall plates have 16" and 24" mounting slot positions. 3. Place the wall plate to the reference line and mark the nine (9) lag bolt mounting points through the wall plate slots on the wall. Mark the wall and the center of the wood studs.
CTM-MS2 4. 5. 6. Level the wall plate with the reference arrow pointing up to the ceiling (Figure 15). Drill six (6) ¼" pilot holes to the marked wall. Secure the plate using the six (6) 5/16" lag bolts and flat washers (Figure 16). Mark the six (6) mounting slot openings 16" Wall Plate Figure 15 Wall Plate 5/16” x 3” Lag Bolts NOTE: Figure 16.
CTM-MS2 Installing the Flat Panel Display (CTM-MS2) WARNING: 1. AT LEAST (2) QUALIFIED PERSONNEL ARE STRONGLY RECOMMENDED FOR INSTALLATION OF THIS PRODUCT. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL. Raise the flat panel with the LEFT and RIGHT mounting brackets secured to the flat panel and insert the top hooks over the upper rod. The lower hooks should rest on the lower rod (Figure 17).
CTM-MS2 2. Make any lateral shift adjustment and lock it by tightening the two (2) M6 x 30mm Phillips screws found on the bottom of the mounting brackets. Use the foot leveler to adjust your plasma. CAUTION: Do not over tighten the M6 x 30mm screws to the rods (Figure 18). NOTE: To remove the display from the wall simply back off the M6 x 30mm screws using a Phillips screwdriver and lift the unit of the wall carefully.
CTM-MS2 3. Tilt the flat panel and secure the two (2) M6 x 12mm safety knobs to each of the mounting brackets (Figure 19). NOTE: To remove the display from the wall simply extend the display to its maximum tilt range, remove the two 6 (mm) safety knurl knobs push the flat panel back to it’s flat position, loosen or remove the two (2) M6 x 30 lateral shift screws and lift the unit of the wall.
CTM-MS2 Technical Specifications 28.000 (171.2) A CL B H 8.000 (203.2) CL 19.000 21.000 (482.6) (533.4) 8.000 (203.2) C 16.000 (406.4) G F E 24.000 (616.97) D 2.331 (59.21) G 12° H 1 19.000 (482.6) 2 A. Wall plate B. Mounting brackets C. Griplate™ D. Mounting hardware E. M6 x 30 (mm) Phillip screws F. Wood stud G. 5/16” x 3” Lag screws and flat washers H.
CTM-MS2 Warranty Limited Lifetime Warranty All Premier Mounts products carry a limited lifetime warranty from ship date against defects in materials and workmanship. Premier Mounts is not liable for improper installation that results in damage to mounts, adapters, display equipment or personal injury. Contact Premier Mounts In the event of missing and/or damage equipment, or technical questions, the following information can help in the completion of the installation.
CTM-MS2 Notes Premier Mounts 3130 E. Miraloma Avenue Anaheim, CA 92806 Phone: (800) 368-9700 Fax: (800) 832-4888 www.mounts.com mounts@mounts.com IN-CTMMS2.
AST-2446/2 Suspension Adapter AST-2446/2 INSTALLATION INSTRUCTIONS 1. 2. 3. 4. 5. Separate the upper pipe and lower tube. Install the upper pipe to the ceiling structure using commercial standards and commercially available suitable hardware (Figure 1). Once the upper pipe has been properly secured to the ceiling structure. Screw the base box or any ceiling adapters to the lower portion of the AST-2446 and secure it with the jam nut (supplied).
AST-2446/2 Suspension Adapter Figure 2. Page 2 Figure 3.
PSD-S PSD-S INSTALLATION INSTRUCTIONS 1. Separate the upper pipe and the lower tube. 2. Install the upper pipe in the ceiling structure using suitable commercial hardware. 3. Screw the lower portion of the PSD-S to the coupling and secure with the Allen screws. 4. Once the upper pipe has been properly installed, insert the lower tube (with the PSD-S attached) inside the upper pipe. 5. Adjust the desired height and lock it with the two (2) through bolts. 6.