User Manual

24 4179V100-UK
Help text overview
Set correct password
Enter advanced setup menu?
Select current input
Select voltage input
Select 0...5 A input range
Select 0...2.5 A input range
Select 0...1 A input range
Select 0...0.5 A input range
Select custom current input range
Select 0...230 V input range
Select 0...120 V input range
Select 0...2.83 V input range
Select 0...1 V input range
Select 0...0.5 V input range
Select custom voltage input range
Select display unit
Select decimal point position
Set display range low
Set display range high
Select current as analog output type
Select voltage as analog output type
Select 0...20 mA output range
Select 4...20 mA output range
Select 4...20 mA with safety readback
Select -10...10 mA output range
Select -20...20 mA output range
Select 0.0...1 V output range
Select 0.2...1 V output range
Select 0...5V output range
Select 1...5V output range
Select 0...10V output range
Select 2...10V output range
Select -1...1 V output range
Select -5...5 V output range
Select -10..10 V output range
Select active output mode
Select passive output mode
Set Analog output response time in seconds
Select Analog Output Function
Enter Language setup
Enter Password setup
Enter Simulation mode
Perform Process calibration
Enter Display setup
Perform Memory operations
Load saved configuration into module
Save configuration in display front
Adjust LCD contrast
Adjust LCD backlight
Write a 6-character device TAG
Analog output value is shown in display line 3
Device TAG is shown in display line 3
Calibrate Input low to process value?
Set value for low calibration point
Calibrate Input high to process value?
Set value for high calibration point
Use process calibration values?
Enable simulation mode?
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
[13]
[14]
[15]
[16]
[17]
[18]
[19]
[20]
[21]
[22]
[23]
[24]
[25]
[26]
Set the input simulation value
Enable password protection?
Set new password
Select language
Select direct output mode
Select inverted output mode
Select V-function output mode
Display underrange
Display overrange
Input underrange
Input overrange
Analog output supply error
Analog output error - check output connections and
reset power
Configuration error - default configuration is loaded
RAM memory error
Invalid configuration
A/D converter error
No communication
Input range limit error - Input outside configurable
input range limit
Invalid configuration type or version
External flash error
Internal flash error
Set input range low
Set input range high
Enable configurable input limit, low
Set configurable input limit, low
Enable configurable input limit, high
Set configurable input limit, high
Select downscale at error
Select zero output at error
Select upscale at error
Select no error action - output undefined at error