Datasheet

4179-103017
Environmental Conditions
Operating temperature................................... -20°C to +60°C
Storage temperature...................................... -20°C to +85°C
Calibration temperature................................. 20...28°C
Relative humidity............................................ < 95% RH (non-cond.)
Protection degree........................................... IP20
Installation in.................................................. Pollution degree 2 &
measurement / overvoltage
cat. II
Mechanical specifications
Dimensions (HxWxD)..................................... 109 x 23.5 x 104 mm
Dimensions (HxWxD) w/ 4501
/ 4511.............................................................
109 x 23.5 x 116 / 131 mm
Weight approx................................................ 250 g
Weight incl. 4501 / 4511 (approx.)................. 285 g / 350 g
DIN rail type................................................... DIN EN 60715/35 mm
Wire size........................................................ 0.13...2.08 mm
2
AWG 26...14
stranded wire
Screw terminal torque.................................... 0.5 Nm
Vibration......................................................... IEC 60068-2-6
2...13.2 Hz...................................................... ±1 mm
13.2...100 Hz.................................................. ±0.7 g
Common specifications
Supply
Supply voltage, universal............................... 21.6...253 VAC, 50...60 Hz or
19.2...300 VDC
Max. required power...................................... ≤ 1.8 W nom.
Internal power dissipation.............................. ≤ 2.5 W
Isolation voltage
Test voltage.................................................... 2.3 kVAC
Working voltage............................................. 250 VAC (reinforced) / 500
VAC (basic)
Response time
Response time (0...90%, 100...10%)............. < 0.75 s
Programming................................................. Communication enabler 4511
/ Programming front 4501
Signal dynamics, input................................... 20 bit
Signal dynamics, output................................. 18 bit
Signal / noise ratio......................................... > 60 dB
Output referred common mode
rejection ratio.................................................
0.02 ppm / VHz
Accuracy........................................................ Better than 0.3% of selected
range*
EMC immunity influence................................ < ±0.5% of span*
Extended EMC immunity: NAMUR
NE21, A criterion, burst..................................
< ±1% of span*
of span........................................................... = of selected standard range
Input specifications
Current input
Signal range................................................... 0...5 AAC / 40...400 Hz
Maximum input limit....................................... 6.00 AAC @ 40°C
Programmable measurement ranges............ 0...0.5; 0…1; 0…2.5 & 0...5
AAC
Custom configurable signal
range..............................................................
0...5 AAC /40...400 Hz
Min. measurement range (span).................... 0.5 AAC
Input resistance.............................................. Nom. < 0.07 Ω
Voltage input
Signal range................................................... 0...300 VAC / 40...400 Hz
Programmable measurement ranges............ 0...0.5, 0...1, 0...2.83, 0…5,
0…120, 0…230 & 0…300
VAC
Custom configurable signal
range..............................................................
0...300 VAC / 40...400 Hz
Min. measurement range (span).................... 0.5 VAC
Input resistance.............................................. Nom. 3 MΩ || 100 pF
Output specifications
Active unipolar and bipolar mA output
Programmable ranges................................... 0...20, 4...20 and S4...20 mA
Programmable ranges................................... ±10 and ±20 mA
Programmable ranges................................... Direct or Inverted Action
Load (@ current output)................................. ≤ 800 Ω
V-curve function, active signals,
100-0-100%...................................................
20-0-20 mA
Passive 2-wire mA output
Programmable ranges................................... 0...20 and 4...20 mA
Programmable ranges................................... Direct or Inverted action
V-curve function, 100-0-100%....................... 20-0-20 mA
External loop supply....................................... 3.5...30 V
Current output
Signal range................................................... 0...23 mA (unipolar)
Signal range................................................... -23...+23 mA (bipolar)
Current limit.................................................... ≤ 28 mA (unipolar)
Current limit.................................................... ± 28 mA (bipolar)
Load stability.................................................. ≤ 0.001% of span / 100 Ω
Response time, programmable...................... 0.0...60.0 s
Voltage output
Programmable signal ranges......................... 0/0.2...1; 0/1...5 ; 0/2...10;
1...0.2/0; 5...1/0; 10...2/0 V
Programmable signal ranges......................... ±1, ±5 and ±10 V
Programmable signal ranges......................... Direct or Inverted action
V-curve function, 100-0-100%....................... 1-0-1, 5-0-5 and 10-0-10 V
Load (@ voltage output)................................ ≥ 500 kΩ
Response time, programmable...................... 0.0...60.0 s
Observed authority requirements
EMC............................................................... 2014/30/EU
LVD................................................................ 2014/35/EU
RoHS.............................................................. 2011/65/EU
Approvals
UL................................................................... UL 508 / C22.2 no. 14
NB
* / **................................................................ For custom configurable
signal ranges, general
accuracy and EMC
specifications are 0.3% of full
scale