Top Clamping Modules TPM Rack Installation Supplement
Installing Mid and End Clamps
Clamps are attached to the Rails using 5/16" RAD Bolts 
Nuts.
Mid Clamps
Mid Clamp tabs must rest 
between the Modules. 
Parts:
5/16" Flange Nut
Mid Clamp
5/16" RAD Bolt 
(length depends on 
module thickness)
Torque: 14-16 ft.-lbs.
End Clamps
Make certain that End 
Clamps are installed as 
shown and not upside 
down.
Parts:
5/16" Flange Nut
End Clamp
5/16" x RAD Bolt 
(length depends on 
module thickness)
Torque: 14-16 ft.-lbs.
and Flange 
This supplement shows how to attach PV Modules on a 
Mount (TPM) rack using the top clamp method. It demonstrates the 
proper use of Mid Clamps and End Clamps along with the associated 
hardware.
Correctly Installing Mid and End Clamps
Mid and End clamps must be installed as shown. Failure to do so could 
lead to personal injury, structural failure and/or damaged components.
Top-of-Pole-
Top Clamping Modules on TPM Rack
Installation Supplement
1
2
3
© 2017 Preformed Line Products Version 1, Rev B, PCN 010617-1, SP3304-3  Top Clamping Modules on a TPM Rack - Installation 1 of 1
End 
Clamp
Installed
upside down
WRONGCORRECT
End 
Clamp
Correctly
Installed
WRONG
Installed with
Modules butted
against Mid 
Clamp Tabs 
Module Frames
Tabs
Mid Clamp
is not
square to 
Modules
Visible gaps
between Mid 
Clamp Tabs and
Modules
CORRECT
1
2
3
Rail
2
1
3
Rail
1
4
2
3
Factory 
Installed
PEM Nut
Rail
Push Modules
against Tabs
of Mid Clamp
2
1
3
Tabs
Rail
Push Modules
against Tabs
of Mid Clamp
1
4
2
3
Tabs