38. When spills of fuel or oil occur, they must be
cleaned up immediately. Dispose of fluids and
cleaning materials as per any local, state, or
federal codes and regulations. Store oil rags in
a bottom-ventilated, covered, metal container.
39. Keep hands and feet away from moving parts.
Do not reach over or across
generator while operating.
40. Before use, check for misalignment or binding of
moving parts, breakage of parts, and any other
condition that may affect the generator’s operation.
If damaged, have the generator serviced
before using. Many accidents are caused
by poorly maintained generators.
41. Use the correct generator for the application.
Do not modify the generator and do not use the
generator for a purpose for which it is not intended.
42. Extension Cord - Make sure your extension cord is
in good condition. When using an extension cord, be
sure to use one heavy enough to carry the current
your product will draw. An undersized extension
cord will cause a drop in line voltage resulting in loss
of power and overheating.
The table below shows the correct cord size to use
depending on cord length and nameplate ampere
rating. If in doubt, use the next heavier gauge.
The smaller the gauge number, the heavier the cord.
RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS
CURRENT
(AMPS)
Load @
120V
(WATTS)
0 ~ 50 ft 50 ~ 75 ft 75 ~ 100 ft
2 240 18 AWG
4 480 18 AWG 16 AWG
6 720 18 AWG 16 AWG 14 AWG
8 960 16 AWG 12 AWG
10 1200 16 AWG 14 AWG 12 AWG
15 1800 14 AWG 12 AWG 10 AWG
20 2400 12 AWG 10 AWG
25 3000 12 AWG 10 AWG 8 AWG
30 3600 10 AWG 8 AWG
35 4200 8 AWG 6 AWG
40 4800 6 AWG
Parallel Kit Precautions
TO PREVENT SERIOUS INJURY, DEATH, AND GENERATOR AND/OR
GENERATOR DAMAGE FROM ELECTRIC SHOCK AND FIRE:
1. Follow Parallel Kit instructions provided with
Kit for connection and use of a Parallel Kit.
2. Only connect two identical Inverter Generators
together using a Parallel Kit.
3. Connect Parallel Kit only to terminals marked
“Parallel Outlets” on the front of the Generator.
4. Do not remove or connect a Parallel Kit
while the Generator is running.
5. Do not use a Parallel Kit that is
attached to only one Generator.