User's Manual
Precyse Technologies, Ltd.
Date: 3 November 2013 Page 7 of 10
Precyse Technologies
100 Ashford Center North
Suite 360
Atlanta, GA 30338
Safety: CE, UL compatible BC91/005010, BC91/005011, BC91/005012, BC91/005013
Class I, Division 1, Groups A,B,C,D -20°C to +50°C, T4: BC91/005014
Environmental:
Size: L120xW90xH50mm
Operating temperature: -20°C to +75°C
Humidity: 90% non-condensing
Enclosure: IP65
Antenna
External antenna:
Manufacturer: Antenna factor
Part number: ANT-916-CW-RH-SMA
Gain: 0dBi
Internal antenna:
Manufacturer: Antenna factor
Part number: SPLATCH 916-SP2
Gain: 0dBi (Peak)
Schematics
Schematics will be provided on demand and under non-disclosure agreement.
System test configuration
Beacon
The unit was configured for normal operation. In this mode the beacon transmits its ID
packet continuously, with 3.2% duty cycle.
For intermodulation tests, the unit was configured to transmit on all 4 channels
simultaneously.
The unit transmission channels were set to 0 (905.0MHz), 8 (911.4MHz) and 15 (917.0MHz).