Hardware & BigComm Software Instruction Manual

BigStuff3 Pro SEFI System
Version 2.1 – February 2011 65
Cell Changes using the “Page Up” & “Page Down” Keys (Fuel and Spark Tables)
Multip
le cell values can also be changed simultaneously using the “Page Up” and “Page Down” keys.
This approach offers a quick alternative to using the mouse. Use the keyboard arrow keys
(up/down/left/right) to maneuver to area of the map where the desired cell changes will be made.
Next, depress and hold the keyboard “Shift” key. Now, use the arrow keys, to maneuver through the
cells to be changed. As the cells are being selected they will become highlighted. Once the desired
cell range has been highlighted, release the “Shift” key. Depress the “Page Up” key to increase the cell
values and the “Page Down” key to decrease the cell values. The cell values will increase or decrease
by a value of one (1) for every keystroke. To exit this mode, depress any one of the arrow keys.
MAP (Kpa) - Engine Load
203
27.8 27.8 27.8 27.8 27.8 27.8 27.8 27.8 27.8 24.8 24.8 24.8 24.8 24.8 24.8 24.8
176
27.8 27.8 27.8 27.8 27.8 27.8 27.8 27.8 27.8 24.8 24.8 24.8 24.8 24.8 24.8 24.8
150
27.8 27.8 27.8 27.8 27.8 27.8 27.8 27.8 27.8 24.8 24.8 24.8 24.8 24.8 24.8 24.8
125
32 27.8 27.8 27.8 27.8 27.8 27.8 27.8 27.8 24.8 24.8 24.8 24.8 24.8 24.8 24.8
111
25 27.8 27.8 27.8 30.5 30.5 30.5 30.5 27.8 27.8 27.8 27.8 27.8 27.8 27.8 27.8
100
25 27.8 27.8 27.8 30.5 30.5 30.5 30.5 27.8 27.8 27.8 27.8 27.8 27.8 27.8 27.8
90
25 27.8 27.8 27.8 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5 30.5
81
25 27.8 27.8 27.8 30.5 32 32 32 32 32 32 32 32 32 32 32
70
25 27 27 30.5 33.3 33.3 34 33 33 33 33 33 33 33 33 33
64
27262633.333.33435343434343434343434
60
26 22 22 28 34 35 36 36 36 36 36 36 36 36 36 36
56
22 18 18 25 35 36 38 40 40 40 40 40 40 40 40 40
50
18 15 15 22 33 35 39 40 40 40 40 40 40 40 40 40
45
15 15 15 22 33 35 39 40 40 40 40 40 40 40 40 40
41
15 15 15 22 33 35 39 40 40 40 40 40 40 40 40 40
28
15 15 15 22 28 33 39 40 40 40 40 40 40 40 40 40
600 800 1,000 1,150 1,200 1,500 1,800 2,000 2,400 2,800 3,200 3,600 4,000 5,000 6,000 7,000
RPM
32. FUEL (F3 – “Quick Key”)
There are several ways to access the base Fuel table. The quickest methods are to hit the F3 key or left
mouse click on the Fuel Table icon, accessible from the main BigComm Screen.
The BigComm software allows the user to configure the Load (MAP)
and RPM axes allowing for a larger number of cells (map area) to be
used for the fuel and spark tables.