User`s guide
E-Prime User’s Guide 
Appendix A: Timing Test Results 
Page A-16 
ACTUAL KEYBOARD RESPONSE DELAY BY VARYING INTERVAL (SINGLE FRAME) 
Varying Interval (ms) 
+1  +2  +3  PRIMES  Grand Total 
Average of ACTUAL DELAY 
6.311  6.483  6.686  5.921  6.450 
StdDev of ACTUAL DELAY 
0.714  0.835  0.715  0.816  0.787 
Min of ACTUAL DELAY 
4.806  4.802  5.800  4.806  4.802 
Max of ACTUAL DELAY 
7.813  7.816  7.816  7.627  7.816 
N (Num of Intervals) 
100  100  100  25  325 
ACTUAL KEYBOARD RESPONSE DELAY BY FIXED INTERVAL (MULTI FRAME) 
Fixed Interval (ms) 
1  100  10000  Grand Total 
Average of ACTUAL DELAY 
6.600  6.594  7.906  6.603 
StdDev of ACTUAL DELAY 
0.820  0.867  0.739  0.848 
Min of ACTUAL DELAY 
4.802  4.803  6.817  4.802 
Max of ACTUAL DELAY 
8.808  13.805  9.815  13.805 
Count of ACTUAL DELAY 
1000  1000  10  2010 
ACTUAL KEYBOARD RESPONSE DELAY BY VARYING INTERVAL (MULTI FRAME) 
Varying Interval (ms) 
+1  +2  +3  PRIMES  Grand Total 
Average of ACTUAL DELAY 
6.786  6.709  6.706  6.600  6.723 
StdDev of ACTUAL DELAY 
0.738  0.683  0.748  0.697  0.720 
Min of ACTUAL DELAY 
5.801  5.800  5.627  5.801  5.627 
Max of ACTUAL DELAY 
7.816  7.816  7.815  7.812  7.816 
Count of ACTUAL DELAY 
100  100  100  25  325 
3b. Mouse Response Test – This test creates a simulated subject response on the mouse 
device. The TS computer plays the role of a subject, as well as that of a recording device. The 
TS computer monitors the display with a photo-diode sensor. When it detects a stimulus, it 
delays for a preset duration, and then toggles a bit, which activates a reed relay. This, in turn, 
activates a modified mouse, as if a subject had pressed a key. This test is run via both single 
frame and multi-frame stimulus presentations in E-Prime. The sample data shows that a 
common mouse is not typically a valid device to use for precision reaction time experiments (e.g., 
both the average delay and standard deviation is generally too high to be considered valid for RT 
experiments). The mouse can be used as an input device, but should only be used for RT 
experiments in which millisecond timing precision is not required. 
ACTUAL MOUSE RESPONSE DELAY BY FIXED INTERVAL (SINGLE FRAME) 
Fixed Interval (ms) 
1  100  10000  Grand Total 
Average of ACTUAL DELAY 
91.380  92.726  95.705  92.071 
StdDev of ACTUAL DELAY 
8.439  8.121  5.131  8.297 
Min of ACTUAL DELAY 
83.802  82.809  87.805  82.809 
Max of ACTUAL DELAY 
247.802  108.811  102.817  247.802 
N (Num of Intervals) 
1000  1000  10  2010 