6. Dimensions and Specifications
Specifications 5209-05 5209-10 5209-16
Weight, pounds (kg) 7.5 (3.4) 10 (4.5) 12.8 (5.8)
Lamp Type QIH240-1000R12 QIH240-2000R12 QIH384-3200R12
Lighted length, Inches (mm) 5 (127) 11 (280) 16 (406)
Rated Voltage 240 240 384
Total Power Dissipated at
Rated Voltage, kW
6 12 19.2
Cooling Water Flow, GPM
(1/min.)
1.0 (3.8) 1.5 (5.7) 2.25 (8.5)
Cooling Air Flow, SCFM
(M/P/min.) (see also fig. 3-2)
4 (0.11) @ 3.0 PSI 4 (0.11) @ 1.0 PSI 4 (0.11) @ 1.0 PSI
With a Regenerative blower
CFM (M/P/min) @ 6.2 PSI
20 (0.57) 20 (0.57) 20 (0.57)
Model Number
Dimensions, Inches (mm)
A B C
5209-05 1.8 (45.7) 5.5 (139.7) 9.10 (231.1)
5209-10 3.73 (94.7) 7.00 (177.8) 14.45 (367.0)
5209-16 3.73 (94.7) 12.63 (320.8) 20.08 (510.0)
Note: The height and width dimensions are identical on all three sizes of the Model 5209.