Instruction Manual
Model 4069E ExtrudeIR
TM
Instruction Manual Introduction
Research, Inc. Page 5 of 26
Specification
* Recommended maximum product diameter for 12-reflector models is two inches.
Recommended maximum product diameter for 18-reflector models is four inches.
** Stated flow rates are for each of two flow paths.
*** Maximum inlet water temperature not to exceed 100° F (37°C)
Model Number*
Lamp Lighted Length,
Inches (mm)
Lamp Wattage
Lamp Type
Lamp Part Number
Lamp Rated Voltage
Wattage Heater, kW
***Water Flow GPM
(LPM)
Pressure Drop Through
Heater @ Required
Water Flow, psi +/- 5psi
Total Weight, Pounds (kg)
4069E-12R-10L-12kW-480V
10
(254)
1000
QIH240-
1000RI2
103390-
003
240 12.0 1.2 (4.5) 10
501
(227)
4069E-12R-16L-19kW-480V
16
(406)
1600
QIH240-
1600RI2
103390-
005
240 19.2 1.8 (6.9) 16
515
(234)
4069E-12R-25L-30kW-480V
25
(635)
2500
QIH480-
2500RI2
103390-
007
480 30.0
2.8
(10.6)**
31
535
(243)
4069E-12R-38L-46kW-480V
38
(965)
3800
QIH480-
3800RI2
103390-
010
480 45.6
4.2
(15.9)**
63
564
(256)
4069E-12R-10L-DUAL-
18kW-480V
10
(254)
1000
QIH240-
1000RI2
103390-
003
240 24 2.4 (9) 20
575
(261)
4069E-18R-10L-18kW-480V
10
(254)
1000
QIH240-
1000RI2
103390-
003
240 18.0 1.7 (6.5) 15
523
(237)
4069E-18R-16L-29kW-480V
16
(406)
1600
QIH240-
1600RI2
103390-
005
240 28.8 2.7 (10.2) 29
550
(249)
4069E-18R-25L-45kW-480V
25
(635)
2500
QIH480-
2500RI2
103390-
007
480 45.0
4.2
(15.7)**
61
588
(267)
4069E-18R-38L-68kW-480V
38
(965)
3800
QIH480-
3800RI2
103390-
010
480 68.4
3.1
(11.9)**
37
639
(290)
4069E-18R-10L-DUAL-
36kW-480V
10
(254)
1000
QIH240-
1000RI2
103390-
003
240 36 3.4 (13) 30
619
(281)