User Manual

Page 7 of 19
Options and Accessories
Lamps -
Lamps for the Model E4 are included with the heater. Table 2-2 displays available lamps for
replacement ordering.
(*) Standard lamp that ships in heater
(**) Lamps are for Horizontal Operation Only
Quartz Liner -
A quartz liner can be provided to protect the reflectors in the heater from contaminants, to
maintain the reflectors at their maximum efficiency. It has a 2.24 inch (57 mm) outer diameter
and a 2.09 inch (53 mm) inner diameter.
Observation Window -
A 0.5 inch diameter window (W) with a quartz cover can be provided in the center of the
chamber side wall, to permit product viewing. With the quartz cover removed, product
temperature can be measured with a suitable optical pyrometer. The observation window is not
available on models ordered with four purging ports. See Figure 3 for Window placement.
Purging Ports -
Purging ports can be provided on two (P) or four (PP) opposing sides of the chamber wall. This
feature allows the heating environment to be force-cooled or inert gas-purged. Purging ports
will not function with a quartz liner installed. See Figure 3 for purge port placement.
Table 2-2: Lamps
Model (P/N)
Heated
Length
Volts Watts Lamp Description
057550-002 2 Inches 120 500 Q500T3/CL
057550-003 2 Inches 120 1000 Q1000T3/4CL (*)
057541-001 5 Inches 120 500 500T3/CL (*)
057550-004 6 Inches 120 1500 Q1500T3/CL (*)
057544-002 10 Inches 240 1000 1000/T3/2CL/HT
057544-005 10 Inches 240 2000 2000/T3/CL/HT (*)
057541-004 16 Inches 240 1600 1600T3/CL
057541-008 16 Inches 240 3000 3000T3/CL (*) (**)
057541-005 25 Inches 480 2500 2500T3/CL (**)
057549-001 25 Inches 480 2500 2500T3/VB/CL (*)
057544-008 25 Inches 600 5000 5MT3/1CL/HT (**)
057541-006 38 Inches 570 3800 3800T3/CL (**)
057549-002 38 Inches 570 3800 3800T3/VB/CL (*)