Model Number*
Lamp Lighted Length,
Inches (mm)
Lamp Wattage
Lamp Type
Lamp Part Number
Lamp Rated Voltage
Wattage Heater, kW
***Water Flow GPM
(LPM)
Pressure Drop Through
Heater @ Required
Water Flow, psi +/- 5psi
Total Weight, Pounds
(kg)
4069-12R-10L-12kW-240V 10 (254) 1000 QIH240-1000RI2 103390-003 240 12.0 1.2 (4.5) 10 85 (39)
4069-12R-10L-12kW-480V 10 (254) 1000 QIH240-1000RI2 103390-003 240 12.0 1.2 (4.5) 10 85 (39)
4069-12R-10L-24kW-240V 10 (254) 2000 QIH240-2000RI2 103390-004 240 24.0 2.3 (8.6) 22 85 (39)
4069-12R-10L-24kW-480V 10 (254) 2000 QIH240-2000RI2 103390-004 240 24.0 2.3 (8.6) 22 85 (39)
4069-12R-16L-19kW-240V 16 (406) 1600 QIH240-1600RI2 103390-005 240 19.2 1.8 (6.9) 16 95 (43)
4069-12R-16L-19kW-480V 16 (406) 1600 QIH240-1600RI2 103390-005 240 19.2 1.8 (6.9) 16 95 (43)
4069-12R-25L-30kW-480V 25 (635) 2500 QIH480-2500RI2 103390-007 480 30.0 1.4 (5.3)** 31 124 (56)
4069-12R-38L-46kW-480V 38 (965) 3800 QIH480-3800RI2 103390-010 480 45.6 2.1 (8.0)** 63 155 (70)
4069-18R-10L-18kW-240V 10 (254) 1000 QIH240-1000RI2 103390-003 240 18.0 1.7 (6.5) 15 112 (51)
4069-18R-10L-18kW-480V 10 (254) 1000 QIH240-1000RI2 103390-003 240 18.0 1.7 (6.5) 15 112 (51)
4069-18R-10L-36kW-480V 10 (254) 2000 QIH240-2000RI2 103390-004 240 36.0 3.3 (12.7) 42 112 (51)
4069-18R-16L-29kW-240V 16 (406) 1600 QIH240-1600RI2 103390-005 240 28.8 2.7 (10.2) 29 140 (64)
4069-18R-16L-29kW-480V 16 (406) 1600 QIH240-1600RI2 103390-005 240 28.8 2.7 (10.2) 29 140 (64)
4069-18R-25L-45kW-480V 25 (635) 2500 QIH480-2500RI2 103390-007 480 45.0 2.1 (7.9)** 61 177 (80)
4069-18R-38L-68kW-480V 38 (965) 3800 QIH480-3800RI2 103390-010 480 68.4 3.1 (11.9)** 37 228 (104)
* Recommended maximum product diameter of 12-reflector models is two inches. Recommended maximum product diameter of 18-reflector model is
four inches.
** Stated flow rates are for each of two flow paths
*** Maximum inlet-water temperature not to exceed 100
°
F (37
°
C)