Manual
Appendix F: MCC iPocket232 User Guide
F-6 Precidia Technologies Inc. 23-CML000293
&Hn FLOW CONTROL
Sets the type of flow control used. The default
is set in configuration.
n = 0 disables flow control
n = 1 selects hardware (CTS/
RTS) flow control
n = 2 selects software (XON/
XFF) flow control
&Sn DSR CONTROL
Sets how the modem drives the DSR signal.
n = 0 (or no option present) sets
the DSR line as always
active (default)
n = 1 sets the DSR line to follow
the connection status
&V VIEW PROFILE SETTINGS
Displays the command and S-register settings.
none
&W SAVE CONFIG
Writes the current configuration settings into
memory. Includes the S-register values, com-
mand options, IP addresses and port numbers.
none
&Z? DISPLAY NUMBERS
Returns the currently configured Remote IP
and Remote Port as “Stored Host #1:
xxx.xxx.xxx.xxx:pppp
” and the Fallback IP
and Fallback Port as “Stored Host #2:
xxx.xxx.xxx.xxx:pppp
”.
none
&Zn=s STORE NUMBER
Stores an IP address and port number (in the
form xxx.xxx.xxx.xxx:pppp) into either the
Remote IP and Port or Fallback IP and Port
locations.
n = 0 Stores as Remote IP and Port
(primary location)
n = 1 Stores as Fallback IP and
Port
Table F.2: Extended AT& and AT+ Commands
Command
Syntax
Description Parameters