Manual
iPocket232 User Guide Appendix F: MCC
23-CML000293 Precidia Technologies Inc. F-3
Table F.1: Supported Commands
Command
Syntax
Description Parameters
A[pppp] ANSWER
Allows the iPocket232 modem to listen for a connec-
tion, or accept a connection on the provided port
[pppp].
Successful connection returns a “CONNECT
<speed>” message. Otherwise, the modem waits
indefinitely, or until a key is pressed to cancel.
If no port number is specified, the modem uses the
configured Local Port. If Local Port is 0, the modem
uses the standard telnet port (23).
The modem provides a “RING” message when an
incoming connection is received and auto-answer is
not active.
NOTE: A telnet program is already listening on port
23 if the Remote Password has been set. If this
command is also input, you will get an “ERROR”
message.
[pppp]
The listening port number,
range 0-65535
Dstring DIAL
Attempts a connection to the specified IP address.
If the IP is specified, but port is not, the modem uses
the telnet port (23).
If a dial string is invalid or not specified, the modem
uses the Remote IP and Remote Port.
If Remote Port is 0, the modem uses the Fallback IP
and Fallback Port.
string =
aaa.bbb.ccc.ddd:pppp
aaa.bbb.ccc.ddd is the IP
address in standard nota-
tion
pppp is the port number (0-
65535)
Note: Any non-digit can
replace the “.” or “:”.
DS=n or
DSn
DIAL STORED
Attempts a connection to a stored IP address and port
number.
n = 0 (or no option present)
uses Remote location
n = 1 uses Fallback loca-
tion
En ECHO
Allows host commands to be echoed.
n = 0 (or no option present)
will disable echo
n =1 enables command
mode echo (default)