The following table lists all possible error codes that may appear in the system log.
Table 7.4: System Log Error Messages
Error
No.
Error
1
the i/o request has been scheduled but not completed
2
no more i/o paths are available
3
requested operation was not supported by the driver
4
the provided i/o buffer was not valid
5
requested operation cannot be done in current state
6
too many connections of this type are already open
7
socket connection type (“domain”) is unknown
8
socket protocol type is unknown
9
“socket has already been bound to another port” Check that the port num-
ber is available for use. Change configuration if necessary.
10
requested port number is already in use
11
requested address was not valid for operation
12
operation requires bound port but socket is unbound
13
device is not ready for the requested operation
14
cannot open connection because socket is already connected
15
operation requires connected socket but not connected
16
“data message is too big for transport type” Usually occurs with UDP
mode.
17
requested operation would break this thread -- try later
18
incoming data corruption has been detected
19
no data is available for this operation
20
“no route available from this host to destination host” Check the IP address
of the host. Change configuration if necessary.
21
storage device can accept no more data
22
requested option is not available