Manual

7 Accessing System Information iPocket232 User Guide
58 Precidia Technologies Inc. 23-CML000293
To access the System Status page in configuration mode:
1 Access the iPocket232 Configuration screen either locally or remotely.
2 Choose System Settings from the Device Settings menu.
3 Choose Display System Status from the System Settings sub-menu.
The System Status page appears, as shown below.
Understanding the System Status Page
The System Status page is divided into three sections:
System Uptime
•Serial Port
Network Routing
System Uptime
This describes how long the system has been operational, the loading on the Precidia
device's CPU, and the firmware version of the iPocket232. Table 7.1 describes each
parameter:
iPocket232 Status:
System Uptime
Up 0 days, 0:13:48
Load Average: 5sec=17% 30sec=24% 5min=19% 30min=4%
Firmware Revision: 4.03.00 (2003-04-17)
Port #1 [null] (terminated/tcp-client, connected)
Received Transmitted
Bytes: 77461 Bytes: 10242
Packets: 158 Packets: 195
Avg-BpP: 490 Avg-BpP: 53
Network Routing
Local Network Subnet Mask Gateway Iface Pkts-In Pkts-Out
Pkts-Err
192.168.1.18 192.168.1.0 255.255.255.0 eth 585 451 1
127.0.0.1 127.0.0.0 255.0.0.0 lo 0 0 0
Please hit <return>:
Example of the System Status Page
Table 7.1: System Uptime on the System Status Page
Parameter Description
Time
The length of time the system has been operating since the last
reset in days, hours:minutes:seconds. Note that the time is not
accurate and may drift slightly.
Load Aver-
age
The loading (activity) of the iPocket232 CPU.