Spec Sheet
DIMENSIONS
Product dimencions
Packing dimensions
Capacity
Wall
Clearance
0.61 cu.ft
17.5L
Copa
Express
Back
0"
0mm
Chamber
Dimensions
Height
Width
7 ¼"
183mm
Depth
11 ¼"
287mm
13 ¼"
336mm
Height
Width
Depth
Weight
Width
Depth
Weight
27 ³⁄"
694mm
16"
405mm
30 ³⁄"
780mm
31 ¹⁄"
800mm
16 ¾"
426mm
32"
813mm
Height
Right SideLeft Side
1"
25mm
1"
25mm
The oven must be installed on a base or counter that supports the weight
of the unit (approximately 174 lbs. / 79 kg)
For proper ventilation, a minimum space of 3" (76mm) between the rear of
the oven and the wall is required.
Do not block the air inlets and exhaust outlets located on the bottom and
rear of the oven.
It is not recommended for the unit to be positioned near stoves, deep
fryers, hot plates and other equipment that releases fat, fumes and heat.
The oven must be installed at a leveled and ventilated location.
Improper installation may void the equipment warranty.
GENERAL INSTRUCTIONS
ELECTRICAL SPECIFICATIONS
Voltage
(V)
Phases
Freq.
(Hz)
Power
(kW)
Circuit
(A)
Consum.
(kWh)
Cable Socket
Copa
Express
32A
(2P+T)
USA/
Canada
230
7.2
32
Single
50
5
Europe
220
6.3
32
Single
60
3x4mm²
4.4
Brazil
220
6.3
32
Single
60
4.4
Latin
America 60Hz
32A
(2P+T)
32A
(2P+T)
3x4mm²
3x4mm²
230
7.2
32
Single
50
5
Latin
America 50Hz
32A
(2P+T)
3x4mm²
174lbs
79kg
220lb
100kg
Ensure that the electrical characteristics of the building network are in
accordance with the technical specications located on the data badge
located on rear panel of the unit. The outlet should be located no more than
6ft / 1.8m away from the unit.
This unit must be properly grounded to avoid electrical shock. This unit is
equipped with a 3-prong plug. This plug must be connected to a properly
installed and grounded outlet. In the event of an electrical short, properly
grounding the unit reduces the risk of electrical shock by grounding the
electrical current. The building electrical is the customer's responsibility.
Copa Express
Speed Oven
PRODUCT DIMENSIONS
INSTALLATION
12 ⁄"
(310 mm)
26 ⁄"
(680 mm)
39"
(990 mm)
16"
(405 mm)
14 ⁄"
(357 mm)
23 ⁄"
(592 mm)
4"
(102 mm)
27 ⁄"
(694 mm)
29 ⁄"
(750 mm)
21 ⁄"
(544 mm)
1 ⁄"
(30 mm)
1 ⁄"
(30 mm)
6
(1.8m)
Maximum
Distance
Circuit
Breaker
Air Inlet
Exhaust
Outlet
Power
Cable
Steam
Outlet
27 ⁄"
(700mm)
Cooling
3"
(76 mm)
208
5.7
30
Single
60
3x10AWG
NEMA 6-30
4
240 30
Single
60
3x10AWG
NEMA 6-30
4
6.4