Owner's Manual

10
3.3 Electric Power
Make sure that the electrical characteriscs of building electric network
follow the technical specificaons of the oven which can be found on the
idenficaon plate located on the back panel and in the electrical table
below.
Use a dedicated circuit breaker for the oven, that must be located at least 6
(1.8 m) away from the right sides of the oven.
USA - CANADA
Voltage
Frequency
Power
Circuit Breaker
Consumpon
208/240 V
60 Hz
5.7 kW
30 A
4 kWh
Phases
Single
Cable
Socket
3x10AWG
NEMA 6-30
NEMA 6-30
EUROPA
Voltage
Frequency
Power
Circuit Breaker
Consumpon
230 V
50 Hz
7.2 kW
32 A
5 kWh
Phases
Single
Cable
3x4mm²
Socket
32A(2P+T)
32A(2P+T)
6 
(1.8m)
Maximum
Distance
Circuit
Breaker
Air
inlet
27 "
(700mm)
Power
Cable
Steam
Outlet
Exhaust
Outlet
Cooling