Product Manual

USE AND MAINTENENACE LIGHT TOWER
At the restore stage the mast does not retract completely
1. Handle locked
Loosen completely the handle which prevent from retracting
2. When temperature is quite low, it is possible to nd ice inside the mast
Wait till a sufcient temperature increase and retract the mast completely
3. A gasket is blocked
Try to give pressure to the inlet to open the gasket
4. Mast buckling
Due to overload, to a damage generated by a hit or other, the mast cannot
be completely retracted. It is necessary to dismantle it and proceed with
an extra-ordinary maintenance to be carried out at the Manufacturer’s
premises.
The oodlights do not work
1. Loosening of the cabling clamp
Disconnect the electrical power, retract the mast and the status of the
cabling.
2. Interruption of electrical cable
Disconnect the electrical power, retract the mast and, by means of a tester,
make sure there is continuity in the circuits. If there is a disconnection,
dismount the mast and send it to the Manufacturer for the replacement of
the damaged cable.
13