When pumping, the mast does not extend or extends partially
1. Obstruction or throttling of the pneumatic hose from the pump or from an
external source to the mast
Proceed by cleaning, dismounting and with the possible substitution with an
equivalent spare part.
2. Pump inefciency
Try the pump without the hose; make sure that the air release valve on the
pump itself is open. If the pressure supplied is not enough, please do the
maintenance by replacing the internal gaskets.
3. Check the air discharge valves are closed
Be sure that both (on the pump and on the mast base) are closed.
4. Lock the mast handles
Loosen all the handles to enable a smooth sliding
5. Check the status of the one-way valve
Check the valve (C) positioned on the pump outlet compels the pressure
return. On the contrary, please replace the valve with a proper spare part.
6. Check the mast gasket
Once the leaking gasket has been detected, proceed dismantling the mast
and replace it.