Product Card

MPF - Manual control panel full option
Mounted on the genset and complete of: analogue instrumentation, control, protection
of the generating set, protected through door with lockable handle
INSTRUMENTATION (ANALOGUE)
• Voltmeter with selector switch (3 phases)
• Frequency meter
• Ammeter with selector switch (3 phases)
• Hours-counter
• Fuel level indicator
• Oil pressure indicator
• Engine temperature indicator
COMMANDS
• Start/stop selector switch with key
• Emergency stop button
PROTECTION WITH ALARM
• Low fuel level
• Battery charger failure
• low oil pressure
• high engine temperature
• Earth Fault
PROTECTIONS WITH SHUTDOWN
• Low fuel level
• Battery charger failure
• low oil pressure
• high engine temperature
• Circuit breaker protection: III poles
• Emergency stop button
OTHERS PROTECTIONS
• Panel protected through door with lockable handle
OUT PUT PANEL MPF
ETB- External Terminal Board  ETB
Socket kit  Standard
Individual CB and Earth Fault protection
3P+N+T 400V 63A n 1
3P+N+T CEE 400V 32A n 1
3P+N+T CEE 400V 16A n 1
230V/16A 2P+T CEE n 1
230V/16A SCHUKO n 1