Brochure

!
!
POWER!ENGINEERING!
/RENTAL! 21! GRW!SERIES!
The Butterfly Air Intake Shutoff Valve provides emergency shutdown of a diesel engine. When the positive spring actuated valve closes, it starves
the diesel engine of air and combustible vapor ingested through the air intake line.
Model
Type- description
Technical specifications
Image
Available for
all GRW
models.
ASV
Operating logic:
The diesel engine speed is governed by
controlling the amount of fuel fed to the engine
through its fuel system and internal speed
governor. If a flammable, material is drawn
into the air intake system of a diesel engine it
acts as an additional ungoverned fuel supply.
This additional fuel source can cause the
diesel engine to accelerate or over speed out
of control. This condition is referred to as
diesel engine runaway. The result of a diesel
engine runaway can range from engine
damage to a catastrophic explosion.
Operating the normal shutdown control will
only turn off the engine’s diesel fuel source.
Once the external flammable gas or vapor is
being drawn into the engine intake, it may not
be possible to stop the engine using the
normal engine shutdown. The most effective
way of shutting down a runaway diesel engine
is with an automatic air intake shutoff valve.
An air intake shutoff valve completely blocks
the engine air intake pipe, cutting off both the
external fuel source and the air required to
keep the engine running
SVX Energize To Run Valve
Actuation “fail safe”:
The valves are equipped with
2-coil solenoids. The “Pull”
coil is used to open the valve
when power is initially
applied. The second coil is
the “Hold” coil which is used
to hold the valve open in run
position as long as power is
supplied. When power is cut
off for any reason such as the
detection of an engine
overspeed condition the valve
will close.
The Valves are also powered
and controlled by Emergency
stop button (installed in the
genset)
Designed for -40°C to 150°C
(-40°F to 300°F) intake air
Major components
manufactured of aluminum,
brass, and stainless steel
Corrosion resistant body
components.
Model
Type - description
Technical specifications
Image
GRW22Y
GRW35Y
GRW50Y
GRW67P
GRW95P
GRW115P
GRW165P
GRW180P
GRW210P
ICL
Internal Canopy Lighting system with manual
switch for easy operation even with low
ambient light conditions
Lamp type: LED
Voltage DC: 12V
Manual Switch: ON/OFF
GRW200V
GRW225V
GRW280V
GRW360V
GRW405V
GRW420V
GRW455V
GRW505V
GRW565V
Lamp type: LED
Voltage DC: 24V
Manual Switch: ON/OFF
ASV
Air Shut-Off Valve
ICL
Internal Canopy Lighting system with manual switch