8 SIZE B10
8.1 B10 – POWER RANGE AND MONOBLOCK SELECTION
B10 size cover these power node PRP:
- 50Hz: from 60kVA up to 80kVA
- 60Hz: from 67kVA up to 92kVA
B10 size include these engine brands:
- PERKINS
8.2 B10 – GENSET MODELS @50Hz
Monoblocks selection for Voltages:
400V Three phases 50Hz
230V Three phases 50Hz
GPW Genset
model
Engine
Brand
Engine
model
Engine
emission
level
Alternator
brand
Alternator
model
GPW60P/FS3A
PERKINS
1104D-44TG2
EU Stage 3A
Mecc Alte
ECP32-2M
GPW65P/FS3A
1104D-44TG3
EU Stage 3A ECP32-2M
GPW80P/FNE
1104A-44TG2
Not Emis Cert ECP32-2L
Complete Power outputs according to Voltages available on Product Card.
8.3 B10 – GENSET MODELS @60Hz
Monoblocks selection for Voltages:
480V Three phases 60Hz
440V Three phases 60Hz
GPW Genset
model
Engine
Brand
Engine
model
Engine
emission
level
Alternator
brand
Alternator
model
GPW70P/ST3
PERKINS
1104D-44TG2
EPA Tier 3
Mecc Alte
ECP32-2M
GPW95P/SNE
1104A-44TG2 Non Emis Cert
ECP32-2L
Monoblocks selection for Voltages:
380V Three phases 60Hz
240/120V Three phases 60Hz
240/138V Three phases 60Hz
220V Three phases 60Hz
208V Three phases 60Hz
GPW Genset
model
Engine
Brand
Engine
model
Engine
emission
level
Alternator
brand
Alternator
model
GPW70P/ST3
PERKINS
1104D-44TG2
EPA Tier 3
Mecc Alte
ECP32-2M
GPW95P/SNE
1104A-44TG2 Non Emis Cert
ECP32-2L
Complete Power outputs according to Voltages available on Product Card.