SDS
PPG83-610 PPG CEILING PAINT ONE COAT WHITE
Product name
1
Product code
Date of issue
Version
00424136
20 September 2018
Section 8. Exposure controls/personal protection
TWA: 20 mppcf 8 hours.
TWA: 80 mg/m³ / (%SiO2) 8 hours.
crystalline silica, respirable powder (<10 microns)
ACGIH TLV (United States, 3/2017).
TWA: 0.025 mg/m³ 8 hours. Form:
Respirable
OSHA PEL Z3 (United States, 6/2016).
TWA: 10 mg/m³ / (%SiO2+2) 8 hours. Form:
Respirable
TWA: 250 mppcf / (%SiO2+5) 8 hours. Form:
Respirable
OSHA PEL (United States, 6/2016).
TWA: 50 µg/m³ 8 hours. Form: Respirable
dust
Eye/face protection
:
Environmental exposure
controls
:
Emissions from ventilation or work process equipment should be checked to ensure
they comply with the requirements of environmental protection legislation. In some
cases, fume scrubbers, filters or engineering modifications to the process equipment
will be necessary to reduce emissions to acceptable levels.
Appropriate engineering
controls
:
If user operations generate dust, fumes, gas, vapor or mist, use process enclosures,
local exhaust ventilation or other engineering controls to keep worker exposure to
airborne contaminants below any recommended or statutory limits.
Wash hands, forearms and face thoroughly after handling chemical products, before
eating, smoking and using the lavatory and at the end of the working period.
Appropriate techniques should be used to remove potentially contaminated clothing.
Wash contaminated clothing before reusing. Ensure that eyewash stations and safety
showers are close to the workstation location.
Hygiene measures
:
Individual protection measures
Skin protection
Recommended monitoring
procedures
:
If this product contains ingredients with exposure limits, personal, workplace
atmosphere or biological monitoring may be required to determine the effectiveness of
the ventilation or other control measures and/or the necessity to use respiratory
protective equipment. Reference should be made to appropriate monitoring standards.
Reference to national guidance documents for methods for the determination of
hazardous substances will also be required.
Safety glasses with side shields.
Key to abbreviations
A
Acceptable Maximum Peak
=
ACGIH
=
American Conference of Governmental Industrial Hygienists.
C
=
Ceiling Limit
Potential skin absorption
S
SR
=
Respiratory sensitization
=
Skin sensitization
SS
TD
=
Total dust
Consult local authorities for acceptable exposure limits.
=
Threshold Limit Value
TLV
TWA
=
Time Weighted Average
Fume
=
F
IPEL
=
Internal Permissible Exposure Limit
=
Occupational Safety and Health Administration.
OSHA
R
=
Respirable
OSHA 29 CFR 1910.1200 Subpart Z - Toxic and Hazardous Substances
=
Z
STEL
=
=
Short term Exposure limit values
United States
Page: 6/13