Product Manual
6
CONTROLS
Release the pedal handle lightly with your foot (1), pull back the handle (2) to start the motor.
The brushes and the drum starts rotating. Pulling the handle further without pressing the
pedal, lowers the machine and engages the rotating brushes onto the floor. To stop working,
take the handle to the vertical position.
1
2
OFFON
BEFORE
RESET
WAIT
SECONDS
30
!
PRESS
On/Off Control
Pull Cable Connect / Disconnect Control
Insert the free end of solution cable into the valve body fitted in the auxiliary tank. Press
and twist clockwise to secure the cable end. Similarly, press and twist counter-clockwise to
disconnect the cable end.
Important - Should the machine fail to operate, contact the supplier from whom you purchased the
machine.
Transport/Working Mode Control
Slide this knob to TOP position (Working Mode) to operate the machine. Slide this knob to
BOTTOM position to move the machine and park the machine.
Warning! Keeping the knob in the top position (working mode) and moving the machine will
damage the brushes.
1
2
OFFON
BEFORE
RESET
WAIT
SECONDS
30
!
PRESS
Brush Contact Control
Brush contact with the floor is adjustable in 4 steps, contact is MINIMUM when the knob is
fully down and MAXIMUM when it is fully raised. This helps you to compensate for the wear
of brushes and also to control the scrubbing effect. If the machine does not move when the
handle is lowered, slide the transport/working mode knob up one step.
1
2
OFFON
BEFORE
RESET
WAIT
SECONDS
30
!
PRESS
Solution Control
By pulling the solution control handle up, the cleaning solution is dispensed on the floor. The
solution stops once the solution control handle is released.
1
2
OFFON
BEFORE
RESET
WAIT
SECONDS
30
!
PRESS
Motor Circuit Breaker
In the event of motor getting overloaded due to improper power supply or unexpected
obstruction to the brush/drum rotation, the circuit breaker trips and protects the motor from
damage. If this happens, identify the cause, correct it and, reset the breaker after minimum of
30 seconds from tripping by pressing the circuit breaker button manually and continue working.
1
2
OFFON
BEFORE
RESET
WAIT
SECONDS
30
!
PRESS