OPERATION OF MACHINE
1. Plug power cord into properly grounded power outlet.
2. To turn on machine, click the ON/OFF switch to the ON position.
NOTE: The vacuum does not turn on until step 3.
3. To operate brush and vacuum motor squeeze the brush start triggers.
4. Adjust brush height for proper pick-up.
CIRCUIT BREAKER
Your new wide area vacuum comes equipped with a 15 amp manual
circuit breaker. If the machine does not turn on you will need to check the
circuit breakers.
To reset circuit breakers:
1. Unplug the wide area vacuum cleaner.
2. Check machine for the following:
Full bag, obstructions, clogged brush, brush height set
too low, etc.
3. Press the affected circuit breaker button to reset.
4. Resume operation.
Brush Roll Replacement for the Wide Area Sweeper
Tools:
4mm Allen Wrench
11mm Wrench
Phillips Head Screwdriver
1. Detach belt cover by removing the 4 belt cover screws as shown in
the picture below. This will expose the belt connected to the brush roll.
2. Pull down bumper on long end of sweeper to expose screws.
3. With a 10mm wrench, secure the nut inside of the brush roll and use
a 4mm Allen wrench for the screw. Loosen screws to release the brush
from the vacuum.
4. Pull out old brush roll from the sweeper. This will release the tension
from the belt.
OFF
SWITCH
BRUSH
START
TRIGGER
ON
BRUSH ROLL REPLACEMENT