GROUNDING INSTRUCTIONS
This appliance must be grounded. If it should malfunction or breakdown, grounding provides
a path of least resistance for electric current to reduce the risk of electric shock. This machine
is equipped with a cord having an equipment-grounding conductor and grounding plug. The
plug must be inserted into an appropriate outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
WARNING: Improper connection of the equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician or service person if you are in doubt as to
whether the outlet is properly grounded. Do not modify the plug provided with the appliance-if
it will not fit the outlet, have a proper outlet installed by a qualified electrician.
This appliance is for use on a nominal 115 volt circuit and has a grounding plug that looks like
the plug illustrated in sketch A. Make sure that the appliance is connected to an outlet having
the same configuration as the plug. No adaptor should be used with this appliance.
MACHINE SPECIFICATIONS
Model PF2030
Voltage / Frequency 115 V / 60 Hz
Brush Motor rating 1/4 hp / 2 A
Total power consumption` 14 A
Vacuum motor rating 1512W / 12.6 A
Bag capacity – dry 45.5 qt. / 43 L
Airflow 226 cfm / 384 m3/h
Vacuum – water lift at sealed orifice 71 in / 1804 mm
Filtration - HEPA 99.97% @0.3 micron
Vibration at controls < 2.5 m/s2
Brush width 30 in / 762 mm
Cable length 75 ft. / 23 m
Weight (including cord) 74 lb. / 33.6 kg
Noise level 69.9 dB(A)
Construction class I
Protection IP20
Machine dimensions
Folded: 33” X 31” X 19”/838 x 787 x 483 mm
Operating Position: 33” X 31” X 39”/838 x 787
x 961 mm
A
GROUNDING
PIN
GROUNDING
OUTLET
RECOMMENDED
GROUNDED
OUTLET BO
X
(A)
2