User I/O Connection: This is a standard 15-pin Female D-Sub
Connector...
DB15 Pin #
Signal
1 CAN High
9 CAN Low
8 CAN Common
2 Fault Relay - Closed for Fault
3 Fault Relay - Common
5 Fault Relay - Open for Fault
6 +28 VDC at up to 0.5 Amp
7 Ground
10 Aux. In #1 (contact to ground)
11 Aux. In #2 (contact to ground)
12 Aux. In #3 (contact to ground)
13 Aux. Out #1 (open collector)
14 Aux. Out #2 (open collector)
15 Aux. Out #3 (open collector)
The Form-C Relay is rated at 30 VDC or 30 VAC @ 0.5 Amp. The Aux. lines are
under custom software control.
Also, refer to the DCM000000103 CAN Wiring Guide.
Note that the ASY00420 DB15 Breakout Kit may be ordered to bring the User I/O
connections out to screw terminals for easy wiring...
This 4" x 4" Board mounts onto four 3.5" x 3.5" #6 locations, and includes a 6' DB15
to DB15 Cable.
At the rear of the remote unit are the Power and Battery connections...