In-Hancer Plus BDA
USER MANUAL
DCM000000105
The +28V Power is current limited to about 0.5 ampere maximum.
The Form-C Fault Relay is rated at 30 VDC 30 VAC @ 0.5 Amp.
For the CAN Network wiring, refer to the DCM000000103 CAN Wiring Guide.
The three Auxiliary Inputs are intended for connection to external contact-closures
connected between the input and ground. Each one, if closed, will create a Fault
Condition Auxiliary Input #1 is also available at connector J19.
The three Auxiliary Outputs are intended for connection to external devices such
as relay coils or lamps. The external devices are connected between the output and
+28V. They are rated at 100mA each. Auxiliary Output #1 is intended for use with
the SB-LITE optional
External Status Indicator Lamp, and is available for that application
via connector J2. The function of Auxiliary Output #1 - the Status Light, is...
Normal Operating Conditions - Lighted Steadily.
Fault Conditions - Flashing
Loss of all Power - Off
The other two Auxiliary Outputs are to be custom software configured.
Note that the SB-DB15 DB15 Breakout Kit may be ordered to bring the User I/O
connections out to screw terminals for easy wiring...
This 4" x 4" Board mounts onto four 3.5" x 3.5" #6 locations, and includes a 6' DB15
to DB15 Cable.
For the Weather-Resistant Enclosures use the Data Cables.
Power Supply:
Connected to the internal 28VDC Power Supply.
Battery: Connected to an optional Backup Battery.
RF Connections: As described, these would be configured internally by Kaval.