User's Manual

In-Hancer Plus BDA
USER MANUAL
DCM000000105
As previously described, the core of an In-Hancer Plus BDA is the RF Deck. The
diagram below shows the RF Deck, its
Indicators and Connectors...
RF Deck Connections
RS232 Connectors:
RS232 Port #1 is for connecting directly
to a PC via a straight-through male to
female DB9 cable. The PC interface is
described later.
RS232 Port #2 is for special software
defined interfacing.
Pin#
Signal Direction
1 * DCD Input
2 Tx Output
3 Rx Input
5 Ground
6 +5V Output
7 CTS Input
8 RTS Output
9 * RI Input
* RS232 Port #2 Only !
The +5V is current limited to about 0.5
ampere maximum.
User I/O Connector:
This provides a variety of I/O
functionality via a 15-pin Female D-Sub
Connector...
Pin#
Signal
1 CAN High (isolated)
9 CAN Low (isolated)
8 CAN Com. (isolated)
3 Fault Relay Common
2 Fault Relay - Closed for Fault
5 Fault Relay - Open for Fault
6 +28V Power
7 Ground
10 Auxiliary Input #1
11 Auxiliary Input #2
12 Auxiliary Input #3
13 Auxiliary Output #1
14 Auxiliary Output #2
15 Auxiliary Output #3
Note that the CAN Network connection is optically-isolated, so the CAN Common
line is NOT the same as ground. Auxiliary Output #1 is also available at connector
J2, and Auxiliary Input #1 is also available at connector J19.