User's Manual

In-Hancer Plus BDA
USER MANUAL
DCM000000105
Accessories for
Stainless-Steel
Weather-Resistant
Enclosures
Data Connectors & Cables
For the Stainless-Steel Weather-Resistant Enclosures, if RS232 or User I/O
connections are needed outside of the enclosure, then weather-resistant
connections are required. These are available through cables that mount inside the
enclosure, connect to the RF Deck's Control Board, and then to gasketed 8-pin
connectors that mount on the enclosure bottom.
MODEL & DESCRIPTION
SB-DATA-00 SB-DATA-01 SB-DATA-02 SB-DATA-03 SB-DATA-03A
Pin
Ext Pigtail Relay & I/O CAN & I/O RS232 Ext RS232
1 Black Wire Relay NO CAN-H DCD In
2 White Wire Relay Common CAN-L Tx Out
3 Red Wire Relay NC CAN Common Rx In
4 Green Wire Aux.In #2 Aux.In #2 RI In
5 Brown Wire Aux.Out #2 Aux.Out #2 Ground
6 Blue Wire Aux.Out #3 Aux.Out #3 +5 VDC Power
7 Orange Wire Ground Ground CTS In
8 Yellow Wire +28 VDC Power +28 VDC Power RTS Out
Brings RF Deck
RS232 Ports
back out to a
mating DB9
Connector
Used Outside
Enclosure
Used Inside
Enclosure
Used Inside
Enclosure
Used Inside
Enclosure
Used Outside
Enclosure
Note that the CAN Network connection is
optically-isolated, so the CAN Common line
is NOT the same as ground.
The circular 8-pin connectors have a sealed
cap/cover to protect the connector when not
in use.
Custom cables may be defined.
Printed: 03.10.14,09:37
Revision Date:10/14/03
10