User's Manual

LINKnet™ OFR400 RF MODULES ! USER MANUAL
DCM000000019
Printed: 01.01.20,12:34
Revision Date:1/20/01 7
Software Set-up
The OFR400 module is shipped pre-configured with the following factory set options:
OPTION RANGE OF VALUES DEFAULT VALUE
Frequency See Model Chart Order Specific
Receive Threshold
–110 to -50 dB -89 dB
Receive Hysteresis 1 to 10 dB 2.5 dB
Time Out 0 to 600 Seconds, or none 300 Seconds
Module Enabled On / Off On
Transmit Power Level 20 to 37 dBm Order Specific
In line with the versatility of the LINKnet
TM
Platform, it is possible to re-configure the
OFR400 module in the field. For further information on the modification software
and the PC adapter, contact KAVAL TELECOM INC. by E-mail: info@kaval.com
Default values may be changed when an order is placed. Check your order
confirmation (shipped with modules) for customized values.