User's Manual
MCPS2135 InstallationPlanning and PreparationIntroduction
MCPS2135 System Operation 19
2001 Spectrian Corporation. All rights reserved.
2. Locate the female N-type RF connector labeled “RF OUTPUT” on the
MCPS2135.
3. Screw the male cable connector firmly onto the female RF output
connector of the MCPS2135.
4. Locate the male input RF connector on the end of the coaxial cable from
the RF signal source. Inspect the connector for damage or irregularity,
and fix any problems with the cable or connector before proceeding.
5. Locate the female SMA connector labeled “RF INPUT” on the rear of the
MCPS2135.
6. Screw the male cable connector firmly onto the MCPS2135 female
connector.
3.4.4 Connect Alarm Interface Cables
1. The MCPS2135 provides optional factory-configured connections for dry
contact, TTL, or RS-422 communications and alarm output to the
customer system. Refer to the connector pin-out and descriptions in
Appendix A3for the connections applicable to your MCPS2135.
2. Locate the interface connectors located on the rear of the shelf
subassembly behind the Amplifier Management Module (AMM). Inspect
the connector and clean if necessary; correct any problems with the cable
or connector before proceeding.
3. Connect the male connector or input wires to the connector mounted on
the MCPS2135. Tighten the two screws on the cable connector (if any)
firmly.
3.5 Completing the Installation
3.5.1 Set the MCPS2135 unit address
Each MCPS2135 may be configured with a unique address (0 – 7) for commands
and status reports sent through the RS-422 port.
If this option is included in the MCPS2135, locate the rotary switch on the rear of
the MCPS2135 Amplifier Management Module. Set the switch to the desired
address.
1.1.23.5.2 Verify Installation
Recheck all physical and electrical connections to the MCPS2135 and remedy any
problems discovered.
Once the installation is verified, the MCPS2135 is ready to be set up and placed in
service, as described in the next section.