2.2 Installation Planning
It is important to ensure all planning and site preparation is complete prior to
beginning to install the MCPS2000. This section describes some installation
considerations and the information required before beginning the installation
procedure.
2.2.1 Site Planning Guide
For each MCPS2000 cell site installation, there must be a Site Planning or Site
Engineering guide giving the detailed information on the site considerations, rack
installation, cable connections, and Radio Parameters.
2.2.1.1 Site Considerations
Intended Installations
The MCPS2000 is intended for installation only in restricted access areas (dedicated
equipment rooms, equipment closets, or the like) in accordance with Articles 110-16,
-17, and -18 of the National Electrical Code, ANSI/NFPA No. 70.
Weight
The MCPS2000 shelf and each RF module weigh approximately 20 kg (44 pounds);
the fully equipped system weighs 100 kg (220 pounds). The system must be
installed, using the appropriate mounting kit, into a rack capable of supporting the
unit, and located on a floor or surface capable of supporting the combined weight of
the rack, the MCPS2000, and the installer or technician.
Floor Covering
If you intend to use a floor covering under the MCPS2000, avoid combustible
materials, industrial carpeting, or materials that will permit generation of
electrostatic charges.
Illumination
The MCPS2000 is designed to be installed and serviced under normal workroom
lighting. During installation, room lighting must be bright enough to allow reading
instructions and inspection of modules, but not so bright as to interfere with viewing
the status LED indicators on the front panel. The MCPS2000 should be oriented or
shielded so that direct sunlight does not fall upon the front panel.
Fire Protection
Spectrian recommends that the MCPS2000 installation site be equipped with smoke
detectors and an automatic fire-extinguishing system. In addition, for personnel
safety, the site should be equipped with a portable halogen or CO
2
fire extinguisher.
Altitude
When installing the MCPS2000 above 5000 ft (1542 m), derate the maximum
operating temperature by 2° C per 1000 ft (304 m) above 5000 ft.
Ventilation
The MCPS2000 requires unrestricted airflow around the MCPS2000. The site must
be ventilated or air-conditioned so that ventilation air does not exceed 50° Celsius.