Operations Manual

Field Service Procedures
MCPS2000 System Operation 23
Spectrian Proprietary -- See notice on first page
4.2 Periodic Maintenance
4.2.1 Dust Removal
Keep the air inputs and outputs of the MCPS2000 free of dust or other material that
could block cooling airflow.
4.2.2 Visual Inspection
Periodically visually inspect the MCPS2000 to ensure that all indicators are
functioning normally and that all system interfaces are properly connected.
4.3 Module Replacement
The RF and AMM modules of theMCPS2000 are hot-swappable Field Replaceable
Units (FRUs) which can be removed and inserted while the system is online without
affecting the operation of the other units in the system.
4.3.1 Replacing an RF Module
WARNING: The RF Module is very heavy (20kgs / 44 lbs.) Get assistance if
necessary.
7. Disable the RF Module being replaced by switching the front panel switch to
DISABLE. The ENABLE LED will be RED.
8. Undo the RF Module front panel fastener.
9. Slide the RF Module out of the shelf subassembly.
10. Place the RF module in a safe, static-free location.
11. Insert the replacement RF Module.
12. Fasten the RF Module front panel fastener.
13. The RF Module will automatically ENABLE; the ENABLE LED will be
GREEN.
4.3.2 Replacing an AMM
1. Undo the AMM front panel fasteners.
2. Slide the AMM module out of the shelf subassembly.
3. Place the AMM in a safe, static-free location.
4. Slide the new AMM into the shelf sub-assembly.
5. Fasten the AMM front panel fastener.
6. The POWER LED will be GREEN.